84818
Bis(2-ethylhexyl) sebacate
Selectophore™, ≥97.0%
동의어(들):
Di(2-ethylhexyl) sebacate, Sebacic acid di(2-ethylhexyl) ester, ‘Dioctyl’ sebacate
로그인조직 및 계약 가격 보기
모든 사진(1)
About This Item
Linear Formula:
[-(CH2)4CO2CH2CH(C2H5)(CH2)3CH3]2
CAS Number:
Molecular Weight:
426.67
Beilstein:
1806504
EC Number:
MDL number:
UNSPSC 코드:
26111700
PubChem Substance ID:
NACRES:
NB.61
추천 제품
Grade
for ion-selective electrodes
Quality Level
제품 라인
Selectophore™
분석
≥97.0% (GC)
≥97.0%
양식
liquid
refractive index
n20/D 1.450 (lit.)
bp
212 °C/1 mmHg (lit.)
density
0.914 g/mL at 25 °C (lit.)
SMILES string
CCCCC(CC)COC(=O)CCCCCCCCC(=O)OCC(CC)CCCC
InChI
1S/C26H50O4/c1-5-9-17-23(7-3)21-29-25(27)19-15-13-11-12-14-16-20-26(28)30-22-24(8-4)18-10-6-2/h23-24H,5-22H2,1-4H3
InChI key
VJHINFRRDQUWOJ-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Bis(2-ethylhexyl) sebacate (BEHS) is a plasticizer widely used in preparing ion-selective electrodes.
Visit our Sensor Applications portal to learn more.
애플리케이션
BEHS was used in preparing PVC-membrane anionic-surfactants-selective electrodes.
법적 정보
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
10 - Combustible liquids
WGK
awg
개인 보호 장비
Eyeshields, Gloves
이미 열람한 고객
Mercury (II) ion-selective electrodes based on p-tert-butyl calix [4] crowns with imine units.
Mahajan, Rakesh Kumar, et al.
Analytical Sciences, 20.5, 811-814 (2004)
A new ion-selective electrode for anionic surfactants.
Segui, Ma Jesus, et al.
Talanta, 71.1, 333-338 (2007)
Agata Michalska et al.
Analytical chemistry, 78(15), 5584-5589 (2006-08-02)
Laser ablation inductively coupled plasma mass spectrometry was used to evaluate ion depth profiles across ion-selective membranes. Advantageously, this approach does not require incorporation of additional components (e.g., chromoionophore) in the membrane composition, as compared to that used in typical
P J Anderson et al.
The American review of respiratory disease, 144(3 Pt 1), 649-654 (1991-09-01)
How variable is the deposition of inhaled methacholine (MCH) in the respiratory tract during a challenge test? Does this variability contribute to the variability of airway responsiveness? To examine these questions we estimated the deposition of polydisperse MCH droplets by
Mehdi Azhdarzadeh et al.
Journal of aerosol medicine and pulmonary drug delivery, 28(1), 30-34 (2014-04-03)
The fraction of inhaled particles depositing in the nasal extrathoracic airways determines the amount of particles delivered to the lungs of infants. Electrostatic charge on particles can affect this deposition, and for this reason, deposition of charged aerosol particles in
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.