추천 제품
Grade
for ion-selective electrodes
Quality Level
vapor pressure
2.1 mmHg ( 20 °C)
제품 라인
Selectophore™
분석
≥99.0% (GC)
≥99.0%
형태
liquid
refractive index
n20/D 1.443
n20/D 1.444 (lit.)
bp
215 °C/4 mmHg (lit.)
density
0.92 g/mL at 20 °C (lit.)
적합성
corresponds to standard for filter test
SMILES string
CCCCC(CC)COP(=O)(OCC(CC)CCCC)OCC(CC)CCCC
InChI
1S/C24H51O4P/c1-7-13-16-22(10-4)19-26-29(25,27-20-23(11-5)17-14-8-2)28-21-24(12-6)18-15-9-3/h22-24H,7-21H2,1-6H3
InChI key
GTVWRXDRKAHEAD-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Visit our Sensor Applications portal to learn more.
애플리케이션
Plasticizer for solvent polymeric membrane electrodes.
Tris(2-ethylhexyl) phosphate may be used as an extractant in the extraction of scandium(III) and yttrium(III) from salicylate media.
Tris(2-ethylhexyl) phosphate may be used as an extractant in the extraction of scandium(III) and yttrium(III) from salicylate media.
법적 정보
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Skin Irrit. 2
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
338.0 °F
Flash Point (°C)
170 °C
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Separation of scandium (III) and yttrium (III) by tris (2-ethylhexyl) phosphate (TEHP).
Talanta, 47(2), 413-419 (1998)
[Nihon koshu eisei zasshi] Japanese journal of public health, 52(12), 1021-1031 (2006-02-07)
2-Ethyl-1-hexanol (2E1H) is a volatile organic compound (VOC) which seldom attracts attention in Japan. This study aimed at clarifying changes in its concentration over time, emission sources, and students' symptoms in classrooms of a university building where indoor air was
Analytica chimica acta, 584(2), 302-307 (2007-03-28)
A novel potentiometric zirconium--PVC matrix membrane sensor incorporating bis(diphenylphosphino) ferrocene as an electroactive material and tris(2-ethylhexyl)phosphate as solvent mediator is described. In mixed acetate buffer solution of pH 4.8, the sensor displays a rapid and linear response for zirconium ion
Environmental health perspectives, 65, 271-278 (1986-03-01)
Chronic toxicity and carcinogenicity studies of several phthalic acid esters (PAEs) and compounds containing a 2-ethylhexyl moiety were conducted in Fischer 344 rats and B6C3F1 (hybrid) mice. The compounds studied were phthalic anhydride, di(2-ethylhexyl) phthalate, butyl benzyl phthalate, diallyl phthalate
Solid state nuclear magnetic resonance, 2(6), 289-306 (1993-12-01)
31P Hahn spin echo line shape and proton line shape experiments are reported on bisphenol A polycarbonate (BPAPC)-tris(2-ethylehexyl)phosphate (TOP) systems to study the concentration and temperature dependence of the local dynamics. In an earlier 31P line shape study a lattice
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.