{2-[2-(Fmoc-amino)ethoxy]ethoxy}acetic acid

≥95.0% (HPLC)

동의어(들):

8-(Fmoc-amino)-3,6-dioxaoctanoic acid

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C21H23NO6
CAS Number:
Molecular Weight:
385.41
MDL number:
UNSPSC 코드:
12352106
PubChem Substance ID:
NACRES:
NA.21

Quality Level

분석

≥95.0% (HPLC)

양식

powder

반응 적합성

reagent type: cross-linking reagent

SMILES string

OC(=O)COCCOCCNC(=O)OCC1c2ccccc2-c3ccccc13

InChI

1S/C21H23NO6/c23-20(24)14-27-12-11-26-10-9-22-21(25)28-13-19-17-7-3-1-5-15(17)16-6-2-4-8-18(16)19/h1-8,19H,9-14H2,(H,22,25)(H,23,24)

InChI key

XQPYRJIMPDBGRW-UHFFFAOYSA-N

기타 정보

Hydrophilic, heterobifunctional spacer

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Christian Risinger et al.
ACS infectious diseases, 3(5), 360-367 (2017-02-28)
Detection of type-specific antibodies is an important and essential part of accurate diagnosis, even in silent carriers of herpes simplex virus (HSV)-1 (oral) and HSV-2 (genital) infections. Serologic assays that identify HSV-1 and HSV-2 type-specific antibodies have been commercially available
A.M.P. Koskinen et al.
Bioorganic & Medicinal Chemistry Letters, 5, 573-573 (1995)
Mohadeseh Dastpeyman et al.
Frontiers in chemistry, 9, 627329-627329 (2021-03-20)
Cell penetrating peptides (CPPs) are being increasingly used as efficient vectors for intracellular delivery of biologically active agents, such as therapeutic antisense oligonucleotides (ASOs). Unfortunately, ASOs have poor cell membrane permeability. The conjugation of ASOs to CPPs have been shown
Magdalena Czuban et al.
Materials science & engineering. C, Materials for biological applications, 116, 111109-111109 (2020-08-19)
Implant-associated infections present severe and difficult-to-treat complications after surgery, related to implant biofilm colonization. Systemic administration of antibiotics cannot reach sufficient concentrations at the infected site and may be toxic. Here we describe how mussel-inspired dendritic material coated on a
Simone Fortunati et al.
Sensors (Basel, Switzerland), 19(3) (2019-02-02)
A new amperometric sandwich-format genosensor has been implemented on single-walled carbon nanotubes screen printed electrodes (SWCNT-SPEs) and compared in terms of performance with analogous genoassays developed using the same methodology on non-nanostructured glassy carbon platforms (GC-SPE). The working principle of

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.