추천 제품
Grade
analytical standard
Quality Level
설명
Peptide standard
형태
powder
구성
angiotensin II
Gly-Tyr
Leu enkephalin
Met enkephalin
Val-Tyr-Val
분석물 화학적 분류
amino acids, peptides, proteins
농도
~0.5 mg each component (dried film)
기술
HPLC: suitable
색상
white
응용 분야
food and beverages
호환성
use to QA Reversed phase columns
형식
multi-component solution
저장 온도
−20°C
애플리케이션
HPLC peptide standard mixture has been used for the separation of peptides of proteins in fish plasma samples using liquid chromatography coupled with quadrupole time of flight mass spectrometer (Q-TOF-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
포장
Amber vials containing a dried film composed of approx. 0.5 mg each of Gly-Tyr, Val-Tyr-Val, methionine enkephalin, leucine enkephalin and angiotensin II.
관련 제품
제품 번호
설명
가격
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
이미 열람한 고객
Plasma proteome profiles of White Sucker (Catostomus commersonii) from the Athabasca River within the oil sands deposit
Comparative Biochemistry and Physiology. Part D, Genomics & Proteomics, 19, 181-189 (2016)
Journal of chromatography. A, 1530, 104-111 (2017-11-18)
Computer-aided method-development programs require accurate models to describe retention and to make predictions based on a limited number of scouting gradients. The performance of five different retention models for hydrophilic-interaction chromatography (HILIC) is assessed for a wide range of analytes.
Electrophoresis, 41(21-22), 1832-1842 (2020-05-22)
Dynamic pH barrage junction focusing in CE enables effective signal enhancement, quantitative capture efficiencies, and straightforward optimization. The method is a technical variant of dynamic pH junction focusing. CE separation with dynamic pH barrage junction focusing is compatible with both
Malaria journal, 10, 205-205 (2011-07-28)
A global proteomic strategy was used to identify proteins, which are differentially expressed in the murine model of severe malaria in the hope of facilitating future development of novel diagnostic, disease monitoring and treatment strategies. Mice (4-week-old CD1 male mice)
Measuring and using scanning-gradient data for use in method optimization for liquid chromatography.
Journal of chromatography. A, 1636, 461780-461780 (2020-12-29)
The use of scanning gradients can significantly reduce method-development time in reversed-phase liquid chromatography. However, there is no consensus on how they can best be used. In the present work we set out to systematically investigate various factors and to
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.