Atto 590

BioReagent, suitable for fluorescence, ≥90% (HPLC)

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C37H39ClN2O9
Molecular Weight:
691.17
MDL number:
UNSPSC 코드:
12352108
NACRES:
NA.32

제품 라인

BioReagent

Quality Level

분석

≥90% (HPLC)

형태

powder

제조업체/상표

ATTO-TEC GmbH

λ

in ethanol (with 0.1% trifluoroacetic acid)

UV 흡수

λ: 595-601 nm Amax

적합성

suitable for fluorescence

저장 온도

−20°C

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Atto fluorescent labels are designed for high sensitivity applications, including single-molecule detection. Atto labels have rigid structures that do not show any cis-trans isomerization. Thus these labels display exceptional intensity with minimal spectral shift on conjugation.
Atto 590 shows a molar extinction of 120,000 and QY of 80% in water (90% in ethanol). Decay time is 3.7 ns.
Employed in fluorescence energy transfer, FRET, microscopy.

법적 정보

This product is for Research use only. In case of intended commercialization, please contact the IP-holder (ATTO-TEC GmbH, Germany) for licensing.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Slide 1 of 1

1 of 1

Matthew Antonik et al.
The journal of physical chemistry. B, 110(13), 6970-6978 (2006-03-31)
We establish a probability distribution analysis (PDA) method for the analysis of fluorescence resonance energy transfer (FRET) signals to determine with high precision the originating value of a shot-noise-limited signal distribution. PDA theoretical distributions are calculated explicitly including crosstalk, stochastic
D Wildanger et al.
Journal of microscopy, 236(1), 35-43 (2009-09-24)
The advent of supercontinuum laser sources has enabled the implementation of compact and tunable stimulated emission depletion fluorescence microscopes for imaging far below the diffraction barrier. Here we report on an enhanced version of this approach displaying an all-physics based
Uffe V Schneider et al.
Nucleic acids research, 38(13), 4394-4403 (2010-03-27)
Twisted intercalating nucleic acid (TINA) is a novel intercalator and stabilizer of Hoogsteen type parallel triplex formations (PT). Specific design rules for position of TINA in triplex forming oligonucleotides (TFOs) have not previously been presented. We describe a complete collection
Subunit rotation in a single F0F1-ATP synthase in a living bacterium monitored by FRET.
Seyfert, K.,et al.
Proceedings of SPIE, 7905, 79050K-79050K (2011)
Analysis of replication factories in human cells by super-resolution light microscopy.
Cseresnyes, Z.; et al.
BMC Cell Biology, 10(1), 88-88 (2009)

문서

Fluorescence lifetime measurement is advantageous over intensity-based measurements. Applications include fluorescence lifetime assays, sensing and FLI.

형광 수명 측정은 강도 기반 측정에 비해 유리한 점이 있습니다. 응용분야에는 형광 수명 분석, 감지 및 FLI가 포함됩니다.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.