콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

20562

Supelco

Manual Bubble Flowmeter (Standard Version)

flow meter volume 10 mL, pkg of 1 ea

동의어(들):

FLOWMETER 10CC EA

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41112500

포장

pkg of 1 ea

기술

gas chromatography (GC): suitable

유량계 용적

10 mL

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Bubble flowmeter is a simple and precise way to measure flow rates of gases. It is the most common device for measuring a volumetric flow rate. This unit has a buret of appropriate volume fitted with rubber bulb at the bottom and a side arm. Air is passed into the buret and the bulb filled with soap solution is squeezed. This causes a soap bubble to enter the buret. The time taken for the bubble to travel in considered as known volume, used to calculate the flow rate.
The most basic configuration of a bubble flowmeter is a calibrated tube, a stopwatch, and a good eye. The bubble is timed as it moves up the calibrated tube between two markings. Flow tubes are graduated as follows:
  • 10 mL tube in 1 mL increments
  • 25 mL tube in 5 mL increments
  • 50 mL tube in 10 mL increments
  • 100 mL tube in 20 mL increments
Includes glass flow tube with two magnetic clamps, a short piece of Tygon tubing and a squeeze bulb. Stand not included.

애플리케이션

Bubble flowmeter may be used to manually control the flow at the system outlet during analysis of perfluorobutane (PFB) in the exhaled rat air using respiration-metabolism chamber system and a GC-MS method. Bubble flowmeters can be used to check splitter or detector flow or to calibrate personal pumps for accurate air sampling.

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

The accuracy of the bubble meter method for gas flow measurements
Levy, A
Journal of Scientific Instruments, 41, 449-453 (1964)
Arthur C. Stern
Air Pollution: Measuring, Monitoring, and Surveillance of Air Pollution , 160-160 (1976)
Steinar Uran et al.
Journal of pharmaceutical and biomedical analysis, 39(3-4), 746-751 (2005-06-21)
Sonazoid is a new contrast agent for ultrasound imaging comprising an aqueous suspension of lipid-stabilised perfluorobutane (PFB) gas microbubbles. A respiration-metabolism chamber system was developed to collect exhaled air following intravenous administration of Sonazoid to rats. Analysis of PFB in

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..