콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

22549

Supelco

Modular Rotameter

flow rate 6-300 mL/min

동의어(들):

LOW FLOW FLOWMETER KIT

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41112500

파라미터

6-300 mL/min flow rate

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Rotameters are suitable for low flow measurement. They can only be used on clean fluids. It has a tapered metering tube which is mounted vertically with small end at the bottom and a float which is free to move within the tube. The fluid to be measured enters at the bottom of the tube, passes upwards around the float and out at the top. The increase and decrease of flow causes the float to rise higher or drop to low respectively. The flow rate is hence determined by direct observation of the position of the float in the metering tube.
The modular design of this rotameter allows the unit to be quickly converted to monitor different flow ranges. Each unit includes a rotameter body and two modules, each with two floats installed inside the flow tube (each float has a different working range). The floats are never touched. Instead, the module is simply interchanged.

Connections are 1/8 in. female NPT. Use connector to male NPT fittings to connect into gas delivery system. The rotameter can be installed on a tripod assembly (order tripod assembly separately).

Low Flow Kit (Cat. No. 22549)
Module 1
  • Glass Float: 6-60 mL/min.
  • Stainless Steel Float: 15-150 mL/min.
Module 2
  • Sapphire Float: 11-110 mL/min.
  • Carboloy Float: 30-300 mL/min.

High Flow Kit (Cat. No. 22550-U)
Module 1
  • Glass Float: 38-380 mL/min. - Dark Brown float
  • Stainless Steel Float: 84-840 mL/min. - metallic float
Module 2
  • Sapphire Float: 54-540 mL/min. -Red float
  • Carboloy Float: 125-1250 mL/min. -metalic float

애플리케이션

Calibrated Supelco Rotameter is suitable in mixing medical grade breathable gas with either oxygen or nitrogen.

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Bela G. Liptak
Flow Measurement (1993)
Laura K Smoyer et al.
Genetical research, 82(3), 163-170 (2004-05-12)
The Triplo-lethal locus (Tpl) of Drosophila is both triplo-lethal and haploinsufficient, but the function of the locus is unknown. We have examined Tpl-aneuploid embryos and find that, in both trisomics and monosomics, the midgut shows extensive cell death and the

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.