콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

27600-U

Supelco

Supelco® Helium Purifier

stainless steel fittings, 1/8 in. O.D. Swagelok (nuts and ferrules included)

동의어(들):

Supelco® HELIUM GAS PURIFIER, 1/8IN FITTINGS

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12000000
NACRES:
SB.54

material

stainless steel fittings

Quality Level

피팅

1/8 in. O.D. Swagelok (nuts and ferrules included)

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

This multiple bed trap removes hydrocarbons, moisture, oxygen, carbon monoxide, and carbon dioxide from helium gas streams. The amount of highly effective, high capacity adsorbent material in each bed is optimized so that breakthrough of each contaminant is as close to simultaneous as possible. This avoids the costly replacement observed with other broad-spectrum traps that have exhausted their capacity for one contaminant, but still have capacity for other contaminants. This trap will easily purify 99.997% purity helium to a cumulative level of 100 ppb (hydrocarbons + moisture + oxygen + carbon monoxide + carbon dioxide).

Specifications:
  • Output Purity: 99.99999%
  • Output Efficiency (total): <100 ppb
  • Output Efficiency (hydrocarbons): <20 ppb (as methane)
  • Output Efficiency (moisture): <10 ppb
  • Output Efficiency (oxygen): <2 ppb
  • Output Efficiency (carbon monoxide): <20 ppb
  • Output Efficiency (carbon dioxide): <1ppm
  • Capacity (hydrocarbons): 30 g (as methane)
  • Capacity (moisture): 46 g
  • Capacity (oxygen): 1200mg
  • Max. Flow Rate: 8 L/min.
  • Max. Pressure: 500 psi
  • Max. Temp.: 100 °C

Dimensions for both purifiers
16.5 in. (41..91 cm) long × 2 5/16 in. (6.3 cm) diameter

법적 정보

Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

Health hazardEnvironment

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1A Inhalation - Resp. Sens. 1 - Skin Sens. 1 - STOT RE 2 Inhalation

표적 기관

Lungs

Storage Class Code

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Jorge E Spangenberg et al.
Analytical and bioanalytical chemistry, 411(10), 2031-2043 (2019-02-05)
Recently, we reported that the carbon isotope composition of the solid residues obtained by freeze-drying white and red wines (δ13CWSR) could be used for tracing the water status of the vines whose grapes were used to produce them. Here, we

문서

GC-MS method detects nitrosamines in Valsartan tablets, meeting US FDA guidelines for pharmaceutical quality control.

Cannabis testing regulations include analysis of purity, potency, and contaminants. Learn more about analysis of cannabis for pesticides, mycotoxins, and pyrethrins registered in California by LC-MS/MS and GC-MS/MS Using Ascentis® Express Biphenyl and SLB®-5ms Columns

관련 콘텐츠

Accurately detect and quantify trace nitrosamines (NDMA, NDEA, NEIPA, NDIPA, NDBA, etc.) in pharmaceutical drugs using our complete product portfolio and application guides for LC-MS and GC-MS. Order high-quality reference standards, columns, filters & more.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.