추천 제품
Grade
analytical standard
Quality Level
CofA
current certificate can be downloaded
포장
ampule of 5000 mg
기술
HPLC: suitable
gas chromatography (GC): suitable
bp
384 °C (lit.)
mp
105-110 °C (lit.)
응용 분야
environmental
형식
neat
저장 온도
2-30°C
SMILES string
c1ccc-2c(c1)-c3cccc4cccc-2c34
InChI
1S/C16H10/c1-2-8-13-12(7-1)14-9-3-5-11-6-4-10-15(13)16(11)14/h1-10H
InChI key
GVEPBJHOBDJJJI-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
FA, a six ringed highly stable compound, is considered as an environmental indicator. It is mainly selected for simulation study.
Fluoranthene (FA) is a polycyclic aromatic hydrocarbon, which can be used in the preparation of fluorescent chemosensors for the specific detection of picric acid.
애플리케이션
FA was used after dissolving in HPLC grade acetonitrile, in order to determine retention data and to study the linearity of the detector, during HPLC analysis of PAH (polycyclic aromatic hydrocarbon).
Fluoranthene (FA) may also be used as an analytical standard for the determination of the analyte in food samples, oils, fats, and environmental samples by various chromatography techniques.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1
Storage Class Code
11 - Combustible Solids
WGK
WGK 2
Flash Point (°F)
388.4 °F - closed cup
Flash Point (°C)
198.0 °C - closed cup
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
이미 열람한 고객
Estimation of polycyclic aromatic hydrocarbons associated with size segregated combustion aerosols generated from household fuels.
Microchemical Journal, Devoted to the Application of Microtechniques in All Branches of Science, 106, 79-86 (2013)
Fluoranthene based fluorescent chemosensors for detection of explosive nitroaromatics
Chemical Communications (Cambridge, England), 48, 5007-5009 (2012)
True Sustainability in Technological Development and Natural Resource Management, 165-165 (2007)
Journal of hazardous materials, 74(1-2), 37-46 (2000-04-27)
For laboratories involved in polycyclic aromatic hydrocarbon (PAH) analyses in environmental samples, it is very useful to participate in interlaboratory comparison studies which provide a mechanism for comparing analytical methods. This is particularly important when PAH analyses are routinely done
Comparison of GC-MS and HPLC for overcoming matrix interferences in the analysis of PAHs in smoked food
Chromatographia, 44(9-10), 497-504 (1997)
문서
Highly accurate HPLC-FLD method for evaluating 15 PAHs in olive oil using Ascentis® Express PAH HPLC column and SPE cleanup, following GB 5009.265-2021.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..