Skip to Content
MilliporeSigma
All Photos(1)

Documents

AX0142

Supelco

Acetonitrile

≥99.9% (GC), gradient grade, suitable for LC/MS, gas chromatography (GC), HPLC, OmniSolv®

Sign Into View Organizational & Contract Pricing

Synonym(s):
ACN, Cyanomethane, Ethyl nitrile, Methyl cyanide
Linear Formula:
CH3CN
CAS Number:
Molecular Weight:
41.05
Beilstein/REAXYS Number:
741857
MDL number:
UNSPSC Code:
12352117
EC Index Number:
200-835-2

vapor density

1.41 (vs air)

Quality Level

vapor pressure

72.8 mmHg ( 20 °C)
97 hPa ( 20 °C)

product line

OmniSolv®

assay

≥99.9% (GC)

form

liquid

autoignition temp.

973 °F

expl. lim.

16 %

technique(s)

HPLC: suitable
LC/MS: suitable
gas chromatography (GC): suitable

impurities

≤0.02% Water (H2O)
≤0.16 μeq/g Titrable base
≤20 ppm Propionitrile
≤8.0 μeq/g Titrable acid

evapn. residue

≤1 ppm

color

APHA: ≤10

refractive index

n20/D 1.344 (lit.)

bp

81-82 °C (lit.)

mp

−45 °C (lit.)

transition temp

flash point 2 °C

density

0.786 g/mL at 25 °C (lit.)

UV cutoff

≤189 nm

UV absorption

λ: 189 nm Amax: ≤1.00
λ: 195 nm Amax: ≤0.15
λ: 210 nm Amax: ≤0.03
λ: 230 nm Amax: ≤0.005
λ: 250 nm Amax: ≤0.005
λ: 270 nm Amax: ≤0.005

format

neat

shipped in

ambient

storage temp.

room temp

SMILES string

CC#N

InChI

1S/C2H3N/c1-2-3/h1H3

InChI key

WEVYAHXRMPXWCK-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Related Categories

General description

Acetonitrile is a water-soluble polar organic solvent with exceptional solubilizing power, unique chromatographic properties, and ideal spectroscopic characteristics.

Application

Acetonitrile is used as a solvent:
  • To prepare mobile phase for LC/MS analysis of bioactive components in Graviola leaf extracts.
  • In Reversed-phase HPLC.
  • A solvent in chemical synthesis
  • A solvent for sample preparation, including extraction, dilution, and dissolution of compounds prior to analysis.

Preparation Note

Product filtered through a 0.2 μm filter

Analysis Note

Assay (GC)99.9% minColor (APHA)10 maxEvaporation residue1ppm maxFiltered through 0.2 µm filterTo pass testFluorescence (as quinine base)300ppt maxFormClear liquidGradient at 210 nm0.002AU maxGradient at 254 nm0.0003AU maxIdentity (IR-spectrum)ConformsPropionitrile20ppm maxRefractive index (at 20°C)1.343-1.345Titrable acid8.0µeq/g maxTitrable base0.16µeq/g maxUV Abs. at 189 nm1.00AU maxUV Abs. at 195 nm0.15AU maxUV Abs. at 210 nm0.03AU maxUV Abs. at 230 nm0.005AU maxUV Abs. at 250 nm0.005AU maxUV Abs. at 270 nm0.005AU maxUV Cut-off189nm maxWater (H2O)0.02% max

Legal Information

OMNISOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

wgk_germany

WGK 2

flash_point_f

closed cup

flash_point_c

closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Slide 1 of 8

1 of 8

Supelco

Supelco

WX0001

Water

Trifluoroacetic acid HPLC

Supelco

TX1276

Trifluoroacetic acid

Methanol OmniSolv® LC-MS, ≥99.9% (GC)

Supelco

MX0486

Methanol

Isopropyl Alcohol OmniSolv®

Supelco

PX1834

Isopropyl Alcohol

Acetonitrile suitable for HPLC, gradient grade, ≥99.9%

Sigma-Aldrich

34851

Acetonitrile

Isopropyl Alcohol HPLC, Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs

Supelco

PX1838

Isopropyl Alcohol

Supelco

Supelco

WX0008

Water

Supelco

Supelco

WX0004

Water

A photoregulated ligand for the nuclear import receptor karyopherin alpha
Seung Bum P, et al.
Bioorganic & Medicinal Chemistry, 9, 3215-3223 (2001)
Comparison of the sensitivity of evaporative universal detectors and LC/MS in the HILIC and the reversed-phase HPLC modes
Clifford M R, et al.
Journal of chromatography, 877, 4133-4139 (2009)
Bioefficacy of Graviola leaf extracts in scavenging free radicals and upregulating antioxidant genes
Yu-Ra S, et al.
Food & Function, 7, 861-871 (2016)

Articles

An accurate and precise HPLC-PDA measurement of 32 cannabinoids and 2 cannflavins in hemp samples using a single extraction in less than 32 minutes.

Related Content

The 4L M-Bottle provides safe handling of solvents due to an innovative solvent bottle design with sealing technology to eliminate leaks and reduce risks in solvent dispensing.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service