Documents

21479

Supelco

Methyl decanoate

analytical standard

Sign Into View Organizational & Contract Pricing

Synonym(s):
Capric acid methyl ester, Decanoic acid methyl ester, Methyl caprate
Linear Formula:
CH3(CH2)8COOCH3
CAS Number:
Molecular Weight:
186.29
Beilstein/REAXYS Number:
1759170
EC Number:
MDL number:
PubChem Substance ID:
NACRES:
NA.24

grade

analytical standard

Quality Level

assay

≥99.0% (GC)

shelf life

limited shelf life, expiry date on the label

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

refractive index

n20/D 1.425 (lit.)
n20/D 1.426

bp

108 °C/10 mmHg
224 °C (lit.)

mp

−14-−11 °C (lit.)

density

0.871 g/mL at 20 °C (lit.)

application(s)

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

format

neat

functional group

ester

shipped in

ambient

storage temp.

room temp

SMILES string

CCCCCCCCCC(=O)OC

InChI

1S/C11H22O2/c1-3-4-5-6-7-8-9-10-11(12)13-2/h3-10H2,1-2H3

InChI key

YRHYCMZPEVDGFQ-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
W505501PHR3535PHR3204
Methyl decanoate analytical standard

21479

Methyl decanoate

Methyl decanoate ≥99%, FG

W505501

Methyl decanoate

Methyl Caprate pharmaceutical secondary standard, certified reference material

PHR3535

Methyl Caprate

Methyl Caprate certified reference material, pharmaceutical secondary standard

PHR3204

Methyl Caprate

grade

analytical standard

grade

FG, Fragrance grade, Halal

grade

certified reference material, pharmaceutical secondary standard

grade

certified reference material, pharmaceutical secondary standard

application(s)

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

application(s)

flavors and fragrances

application(s)

pharmaceutical

application(s)

pharmaceutical

format

neat

format

-

format

-

format

-

assay

≥99.0% (GC)

assay

≥99%

assay

-

assay

-

shelf life

limited shelf life, expiry date on the label

shelf life

-

shelf life

-

shelf life

-

General description

Methyl decanoate, also known as methyl caprate, is a decanoate ester and belongs to the group of fatty acid methyl esters (FAMEs). It is naturally found in Saccharomyces cerevisiae, Astragalus mongholicus, Achillea millefolium, and others.

Application

This analytical standard can also be used as follows:

  • Gas chromatography-tandem differential mobility spectrometry (DMS) based separation and quantification of 16 methyl- and ethyl- fatty acid esters from biodiesel samples
  • Development and validation of a gas chromatography-flame ionization (GC-FID) method to determine fatty acid methyl esters (FAMEs) in beer wort samples following their solid phase extraction and BF3 based methylation
  • Multi-residue analysis of 76 volatile compounds from jujube extract samples by gas chromatography-mass spectrometry (GC-MS) after their extraction by steam distillation combined with drop-by-drop extraction
  • Comparative analysis of gas chromatography-combustion-mass spectrometry and gas chromatography-flame ionization detector methods for the determination of fatty acid methyl esters (FAMEs) in biodiesel samples
  • Identification and quantification of fatty acids in walnut and coconut oil samples by gas chromatography-mass spectrometry (GC-MS) after their methyl esterification by BF3-MeOH method
  • Simultaneous determination of fatty acids in bovine colostrum samples by GC-FID after their derivatization to ester forms using an acidic catalyst boron trifluoride

Other Notes

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Recommended products

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

pictograms

Environment

signalword

Warning

hcodes

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 2

Storage Class

10 - Combustible liquids

wgk_germany

WGK 1

flash_point_f

230.9 °F - Pensky-Martens closed cup

flash_point_c

110.5 °C - Pensky-Martens closed cup

ppe

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 6

1 of 6

Methyl stearate analytical standard

Supelco

85769

Methyl stearate

Methyl caprylate United States Pharmacopeia (USP) Reference Standard

USP

1424255

Methyl caprylate

Methyl caproate United States Pharmacopeia (USP) Reference Standard

USP

1424244

Methyl caproate

Methyl laurate certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Supelco

07041

Methyl laurate

Methyl laurate ≥98%, FG

Sigma-Aldrich

W271500

Methyl laurate

Methyl caprate United States Pharmacopeia (USP) Reference Standard

USP

1424233

Methyl caprate

Experimental and kinetic modeling study of extinction and ignition of methyl decanoate in laminar non-premixed flows.
Seshadri K, et al.
Proceedings of the Combustion Institute, 32(1), 1067-1074 (2009)
Identification and quantification of trans fatty acids in bakery products by gas chromatography-mass spectrometry after dynamic ultrasound-assisted extraction.
Ruiz-Jimenez J, et al.
Journal of Chromatography A, 1045(1-2), 203-210 (2004)
Hanneke Brust et al.
Journal of chromatography. A, 1374, 224-230 (2014-12-10)
In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times; the analysis of impurities in TNT was performed
Oier Aizpurua-Olaizola et al.
Journal of food science, 80(1), E101-E107 (2014-12-05)
In this study, supercritical fluid extraction has been successfully applied to a sequential fractionation of fatty acids and polyphenols from wine wastes (2 different vitis vinifera grapes). To this aim, in a 1st step just fatty acids were extracted and
Brian D Fitz et al.
Journal of chromatography. A, 1392, 82-90 (2015-03-31)
Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at

Articles

Efficient separation of various fatty acids and esters using chromatography for analytical and industrial purposes.

Protocols

Separation of Methyl decanoate; Methyl dodecanoate; Methyl myristate; Methyl palmitate; Methyl caprylate; Methyl oleate; Methyl linoleate; Methyl linolenate; Methyl stearate

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service