MilliporeSigma
All Photos(1)

Documents

40060

Supelco

N-Nitrosodiphenylamine solution

certified reference material, 5000 μg/mL in methanol

Sign Into View Organizational & Contract Pricing

Synonym(s):
N-Nitroso-N-phenylaniline, Diphenylnitrosamine, Diphenylnitrosoamine
CAS Number:
EC Number:

grade

certified reference material
TraceCERT®

Quality Level

agency

EPA 625,8270,Mar ′90, Dec ′90, Aug ′91 Statement of Work
EPA OLM04 (Statement of Work)

product line

TraceCERT®

CofA

current certificate can be downloaded

feature

standard type calibration

packaging

ampule of 1 mL

concentration

5000 μg/mL in methanol

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

environmental

format

single component solution

storage temp.

2-8°C

InChI

1S/C12H10N2O/c15-13-14(11-7-3-1-4-8-11)12-9-5-2-6-10-12/h1-10H

InChI key

UBUCNCOMADRQHX-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
40458CRM4048548146
Supelco

40060

N-Nitrosodiphenylamine solution

1-Nitrosopiperidine solution certified reference material, 5000 μg/mL in methanol

40458

1-Nitrosopiperidine solution

Supelco

CRM40485

n-Nitrosomorpholine solution

format

single component solution

format

single component solution

format

single component solution

format

single component solution

grade

certified reference material, TraceCERT®

grade

certified reference material, TraceCERT®

grade

certified reference material, TraceCERT®

grade

certified reference material, TraceCERT®

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-30°C

packaging

ampule of 1 mL

packaging

ampule of 1 mL

packaging

ampule of 1 mL

packaging

ampule of 1 mL

concentration

5000 μg/mL in methanol

concentration

5000 μg/mL in methanol

concentration

5000 μg/mL in methanol

concentration

-

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 3 - Flam. Liq. 2 - STOT SE 1

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

49.5 °F

flash_point_c

9.7 °C


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Krzysztof Piech et al.
Journal of the American Chemical Society, 129(11), 3211-3217 (2007-03-03)
A new method for investigating the mechanisms of nitric oxide release from NO donors under oxidative and reductive conditions is presented. Based on the fragmentation of N-nitrosoamines, it allows generation and spectroscopic characterization of nitrenium cations, amide anions, and aminyl
S E Atawodi et al.
European journal of drug metabolism and pharmacokinetics, 15(1), 27-29 (1990-01-01)
Pharmacokinetic investigations into the biliary excretion of N-nitrosodiphenylamine given as an i.p. dose of 50 mg/kg were conducted and results compared in three animal species; rat, guinea pig and rabbit following bile duct cannulation and collection of bile in vitro.
The genetic toxicology of N-nitrosodiphenylamine.
D McGregor
Mutation research, 317(3), 195-211 (1994-06-01)
K E Appel et al.
Archives of toxicology, 60(1-3), 204-208 (1987-01-01)
Nitrosodiphenylamine was tested for induction of DNA single strand breaks in rat hepatocytes and Chinese hamster V 79 cells with the alkaline filter elution assay. While in rat hepatocytes DNA damage could be observed, negative results were obtained in V
A el-Yazigi et al.
Therapeutic drug monitoring, 17(5), 511-515 (1995-10-01)
A rapid and expedient liquid chromatographic method for the analysis of paclitaxel in plasma is described. Paclitaxel and the internal standard (IS, N-nitrosodiphenylamine) were separated on a 10-microns particle, 8 mm x 10 cm C18 cartridge in conjunction with a

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service