MilliporeSigma
All Photos(1)

55234-U

Supelco

Supel QuE

Acetate Tube, pk of 50, AOAC® 2007.01

Synonym(s):
QuEChERS
NACRES:
NB.21

material

polypropylene tube

Quality Level

Agency

AOAC® 2007.01

product line

Supel

composition

magnesium sulfate, 6 g
sodium acetate, 1.5 g (Cat. No. 58750)

packaging

pk of 50

technique(s)

QuEChERS: suitable

centrifuge tube volume

15 mL

application(s)

food and beverages

separation technique

ion exchange

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
55288-U55289-U55287-U
Supelco

Supelco

55234-U

Supel QuE

Supelco

Supelco

55288-U

Supel QuE

Supelco

Supelco

55289-U

Supel QuE

Supelco

Supelco

55287-U

Supel QuE

agency

AOAC® 2007.01

agency

AOAC® 2007.01

agency

AOAC® 2007.01

agency

AOAC® 2007.01

product line

Supel

product line

Supel

product line

-

product line

-

composition

magnesium sulfate, 6 g

composition

Discovery® DSC-18, 50 mg , magnesium sulfate, 150 mg , Supelclean PSA, 50 mg

composition

Discovery® DSC-18, 50 mg (;), ENVI-Carb, 50 mg , magnesium sulfate, 150 mg , Supelclean PSA, 50 mg

composition

magnesium sulfate, 150 mg , Supelclean PSA, 50 mg

packaging

pk of 50

packaging

pack of 100

packaging

pack of 100

packaging

pack of 100

technique(s)

QuEChERS: suitable

technique(s)

QuEChERS: suitable

technique(s)

QuEChERS: suitable

technique(s)

QuEChERS: suitable

General description

Dispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products.

Using the QuEChERS method, food/agricultural samples are first extracted with an aqueous miscible solvent (e.g., acetonitrile) in the presence of high amounts of salts (e.g., sodium chloride and magnesium sulfate) and/or buffering agents (e.g. citrate) to induce liquid phase separation and stabilize acid and base labile pesticides, respectively. Upon shaking and centrifugation, an aliquot of the organic phase is subjected to further cleanup using SPE. Unlike traditional methods using SPE tubes, in dispersive SPE, cleanup is facilitated by mixing bulk amounts of SPE (e.g., Supelclean PSA, ENVI-Carb, and/or Discovery DSC-18) with the extract. After sample cleanup, the mixture is centrifuged and the resulting supernatant can either be analyzed directly or can be subjected to minor further treatment before analysis.

Supelco carries a line of vials and centrifuge tubes containing pre-determined amounts of salts and SPE sorbents to support the most common method configurations used today.

Suitability

Suitable for extracting 10-15 g food/agricultural sample. The high level of salts (e.g. magnesium sulfate) is to induce phase separation between the acetonitrile and aqueous sample layer.

Legal Information

AOAC is a registered trademark of AOAC International
Supel is a trademark of Sigma-Aldrich Co. LLC

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 3

1 of 3

Supelco

Supelco

55295-U

Supel QuE

Supel™ QuE Verde Tube, centrifuge tube volume 15 mL, pack of 50 ea

Supelco

55442-U

Supel QuE Verde

Calogero Di Bella et al.
Frontiers in public health, 8, 273-273 (2020-08-01)
Heavy metals and PAHs were measured in animal foodstuffs from Augusta-Melilli-Priolo area in order to evaluate the potential human health risk associated to their consumption. All heavy metals were detected in seafood products while most of them were <LOD in
Steven J Lehotay et al.
Journal of chromatography. A, 1217(16), 2548-2560 (2010-02-11)
This article describes the comparison of different versions of an easy, rapid and low-cost sample preparation approach for the determination of pesticide residues in fruits and vegetables by concurrent use of gas and liquid chromatography (GC and LC) coupled to
Lijun Han et al.
Analytica chimica acta, 827, 40-46 (2014-05-17)
A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe)
Yelena Sapozhnikova et al.
Analytica chimica acta, 758, 80-92 (2012-12-19)
A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated using
M Picot Groz et al.
The Science of the total environment, 493, 162-169 (2014-06-20)
The UV filters and musk fragrances have come into focus because these compounds are contained and increasingly used not only in sunscreen products but also in many products of daily use, such as cosmetics, skin creams, plastics or varnish. In

Articles

Determination of Neonicotinoids in Honey using a Chromolith RP-18 HPLC column and UV Detection

Determination of Neonicotinoids in Honey using a Chromolith RP-18 HPLC column and UV Detection

Protocols

LC/MS/MS Analysis of Neonicotinoid Pesticides in Dandelion Blossoms on Ascentis® Express C18 after Dispersive SPE (QuEChERS) using Supel™ QuE

LC/MS/MS Analysis of Neonicotinoid Pesticides in Dandelion Blossoms on Ascentis® Express C18 after Dispersive SPE (QuEChERS) using Supel™ QuE

Banned and Other Neonicotinoids from Plant Material

On Friday, April 27, 2018, the European Union decided to ban the use of three neonicotinoid insecticides from use on field crops, having deemed them dangerous to bees. This application demonstrates the analysis of these banned compounds and others from dandelion blossoms using QuEChERS and LC-MS.

Solid Phase Extraction: Normal Phase Methodology

Retention occurs through polar interaction between the sorbent and analytes. Typical sample matrices that can be employed in normal-phase SPE include hydrocarbon or fatty oils diluted in a solvent like hexane, isooctane, chlorinated solvent, THF, diethyl ether, or ethyl acetate.

Related Content

Gas Chromatography (GC)

Gas chromatography is a common analytic technique used to separate and analyze volatile compounds in the gas phase. GC is applied in many industries for quality control, and to identify and/or quantify compounds in a mixture.

QuEChERS Sample Preparation Method

QuEChERS is a ‘Quick, Easy, Cheap, Effective, Rugged and Safe’ sample cleanup method used to prepare food and agricultural samples for pesticides analysis. QuEChERS is based on the Solid Phase Extraction (SPE) technique of sample preparation.

Chromatograms

application for SPE, suitable for GCsuitable for GC, application for SPE

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service