MilliporeSigma
All Photos(3)

55261-U

Supelco

HybridSPE®-Phospholipid

Cartridge, bed wt. 30 mg, volume 1 mL, pk of 100

NACRES:
NB.21

material

PE frit (20 μm)
polypropylene hardware

product line

HybridSPE®

composition

bed wt., 30 mg

packaging

pk of 100

technique(s)

solid phase extraction (SPE): suitable

volume

1 mL

matrix active group

zirconia-based phase

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
55267-U55276-U52798-U
HybridSPE®-Phospholipid Cartridge, bed wt. 30 mg, volume 1 mL, pk of 100

Supelco

55261-U

HybridSPE®-Phospholipid

HybridSPE®-Phospholipid Cartridge, bed wt. 500 mg, volume 6 mL, pk of 30

Supelco

55267-U

HybridSPE®-Phospholipid

HybridSPE®-Phospholipid Cartridge, bed wt. 30 mg, volume 1 mL, pk of 200, polypropylene material (hardware), PE frit (20 μm)

Supelco

55276-U

HybridSPE®-Phospholipid

HybridSPE®-Phospholipid Small Volume 96-well Plate, bed wt. 15 mg, volume 0.8 mL, pk of 20

Supelco

52798-U

HybridSPE®-Phospholipid

composition

bed wt., 30 mg

composition

bed wt., 500 mg

composition

bed wt., 30 mg

composition

bed wt., 15 mg

packaging

pk of 100

packaging

pk of 30

packaging

pk of 200

packaging

pk of 20

volume

1 mL

volume

6 mL

volume

1 mL

volume

0.8 mL

matrix active group

zirconia-based phase

matrix active group

zirconia-based phase

matrix active group

zirconia-based phase

matrix active group

zirconia-based phase

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100

General description

HybridSPE-Phospholipid technology is a simple and generic sample prep platform designed for the gross level removal of endogenous protein and phospholipid interferences from biological plasma and serum prior to LC-MS or LC-MS/MS analysis. Biological plasma or serum is first subjected to protein precipitation via the addition and mixing of acidified acetonitrile. Precipitated proteins are then removed by centrifugation and the resulting supernatant is loaded on the HybridSPE-Phospholipid 96-well plate or cartridge which acts as a chemical filter that specifically targets the removal of endogenous sample phospholipids. The phospholipid retention mechanism is based on a highly selective Lewis acid-base interaction between the proprietary zirconia ions functionally bonded to the HybridSPE-Phospholipid stationary phase and the phosphate moiety consistent with all phospholipids. The resulting eluent is ready for immediate LC-MS or LC-MS-MS analysis.

The "In-well" and "In-cartridge" precipitation methods are available for the HybridSPE-Phospholipid 96-well version and HybridSPE-Phospholipid Ultra cartridge in which biological plasma/serum is first added to either the well or cartridge, followed by acidified acetonitrile (precipitation agent). After a brief mixing/vortexing step, vacuum is applied. Because the 96-well and Ultra cartridge versions contain a series of low porosity hydrophobic filters/frits, the packed-bed filter/frit assembly acts as a depth filter facilitating the concurrent removal of both phospholipids and precipitated proteins during the extraction process. Standard HybridSPE-Phospholipid cartridges require an "off-line" precipitation method.

Features and Benefits

  • For use in conjunction with off-line protein precipitation.
  • Merges the simplicity of protein precipitation and the selectivity of SPE via the targeted removal of phospholipids
  • Reduce ion-suppression through the complete removal of phospholipids and precipitated proteins
  • 2-3 step generic procedure
  • Minimal to no method development
  • Available in 96-well and 1 mL cartridge dimensions

Legal Information

HybridSPE is a registered trademark of Sigma-Aldrich Co. LLC

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Junji Ohnishi et al.
Human genomics, 11(1), 21-21 (2017-09-04)
Growing evidence suggests that spiritual/religious involvement may have beneficial effects on both psychological and physical functions. However, the biological basis for this relationship remains unclear. This study explored the role of spiritual/religious involvement across a wide range of biological markers
Sara Anjos et al.
Journal of proteome research, 18(8), 3174-3183 (2019-07-11)
Obesity is a public health problem and a risk factor for pathologies such type 2 diabetes mellitus, cardiovascular diseases, and nonalcoholic fatty liver disease. Given these clinical implications, there is a growing interest to understand the pathophysiological mechanism of obesity.
Takahiko Mitsui et al.
International urology and nephrology, 52(2), 233-238 (2019-10-07)
The present study was conducted to identify metabolites using a metabolomics approach and investigate the relationship between these metabolites and urgency as a major symptom of overactive bladder (OAB). In 47 male participants without any apparent neurological disease, OAB was
Seiichiro Sakao et al.
Molecular medicine reports, 23(4) (2021-01-27)
It is generally considered that there is an increase in glycolysis in the hypertrophied right ventricle (RV) during pulmonary hypertension (PH), which leads to a decrease in glucose oxidation through the tricarboxylic acid (TCA) cycle. Although recent studies have demonstrated
Marie Bagge Jensen et al.
Food chemistry, 345, 128835-128835 (2020-12-16)
Growing evidence of vitamin K's importance in human health beyond blood coagulation and bone health necessitates its further research. A method involving extraction, lipase treatment, clean-up, and detection and quantification by LC-ESI-MS/MS of phylloquinone (PK), menaquinone-4 (MK-4), menaquinone-7 (MK-7) and

Articles

Vitamin D epi-Metabolites Separated with HybridSPE-Phospholipid

This Sigma-Aldrich article continues to detail new methodology for the analysis of Vitamin D metabolites using HybridSPE-Phospholipid technology.

Ion-Suppression & Phospholipid Contamination

We are presenting an article focusing on ion-suppression and phospholipid contamination and some of their major causes and difficulties.

HybridSPE-Phospholipid Technology

This Sigma-Aldrich article discusses how the HybridSPE-Phospholipid Technology works and how the phospholipids are removed.

Protocols

Enrichment of Phospholipids in Biological Samples Using HybridSPE-PL

A simple method to enrich phospholipids from plasma samples, involving a HybridSPE-PPT 96-well plate that both retains phospholipids and removes precipitated proteins.

Related Content

Small Molecule HPLC

Small molecules are ions and compounds of molecular weight typically less than 900 daltons. These compounds can be effectively separated and analyzed by HPLC, UHPLC and LC-MS using mainly silica particles or monolithic stationary phases with a broad range of column chemistries (modifications).

Chromatograms

application for HPLC

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service