추천 제품
Quality Level
분석
≥99%
형태
solid
mp
138-140 °C (lit.)
solubility
soluble 1%, clear, colorless to faintly yellow (1N HCl)
SMILES string
CCN(CC)CCNC(=O)c1ccc(NC(C)=O)cc1
InChI
1S/C15H23N3O2/c1-4-18(5-2)11-10-16-15(20)13-6-8-14(9-7-13)17-12(3)19/h6-9H,4-5,10-11H2,1-3H3,(H,16,20)(H,17,19)
InChI key
KEECCEWTUVWFCV-UHFFFAOYSA-N
일반 설명
The relaxant effects of N-acetylprocainamide on bovine tracheal smooth muscle was studied.
애플리케이션
N-acetylprocainamide (NAPA) was used as a model drug in the study of establishing a quantitative approach to predict the renal clearances of basic drugs using N-1-methylnicotinamide (NMN).
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences, 13(3), 303-308 (2001-06-01)
The dosage regimen of a drug eliminated predominantly through the kidney need to be adjusted for the patients with renal disease. The objective of the present study was to establish a quantitative approach to precisely predicting the renal clearances of
Multicenter evaluation of the Abbott AxSYM procainamide and N-acetylprocainamide assays: comparison with Abbott TDx/TDxFLx, Syva EMIT 2000, DuPont ACA, and HPLC methods.
Clinical biochemistry, 31(1), 55-58 (1998-04-29)
Journal of autonomic pharmacology, 18(2), 83-87 (1998-09-08)
1. The cardiac anticholinergic effects of procainamide (1 mg kg(-1) min(-1)) and its N-acetylated metabolite (NAPA) at equimolar dose (1.16 mg kg(-1) min(-1)) were studied using in vivo experimental pharmacological and in vitro radioligand binding studies. 2. Procainamide and NAPA
Therapeutic drug monitoring, 18(6), 693-697 (1996-12-01)
The objective of this study was to compare the precision and accuracy of fluorescence polarization immunoassay (FPIA) with high-performance liquid chromatography (HPLC) for measurement of procainamide (PA) and N-acetylprocainamide (NAPA) concentrations in urine. To determine the correlation between FPIA and
Application of capillary electrophoresis to the in vitro assessment of drug metabolism.
Biochemical Society transactions, 23(3), 432S-432S (1995-08-01)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.