추천 제품
Quality Level
분석
99.95% trace metals basis
양식
powder
품질
precipitated
불순물
≤550.0 ppm Trace Metal Analysis
bp
2260 °C (lit.)
density
4.830 g/mL at 25 °C
4.89 g/mL at 25 °C (lit.)
SMILES string
F[Ba]F
InChI
1S/Ba.2FH/h;2*1H/q+2;;/p-2
InChI key
OYLGJCQECKOTOL-UHFFFAOYSA-L
유사한 제품을 찾으십니까? 방문 제품 비교 안내
특징 및 장점
Primary glass modifier in fluorozirconate glasses.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Oral - Acute Tox. 4 Inhalation
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
Lot/Batch Number
Jian Ruan et al.
Optics express, 17(7), 5163-5169 (2009-04-01)
Bi-doped BaF(2) crystal was grown by the temperature gradient technique and its spectral properties were investigated. The absorption, emission and excitation spectra were measured at room temperature. Two broadband emissions centered at 1070 and 1500 nm were observed in Bi-doped
S Tavernier et al.
Medical progress through technology, 17(3-4), 237-241 (1991-01-01)
The work presented is part of a design study for a Positron Emission Tomograph (PET) scanner based on the use of BaF2 scintillator and photosensitive wire chambers. The detection efficiency for gamma radiation of 511 keV is found close to
J Zou et al.
The Journal of biological chemistry, 272(9), 6073-6077 (1997-02-28)
The role of the cytoplasmic regions of interleukin-12 receptors (IL-12R) beta1 and beta2 in stimulating proliferation was examined. The transmembrane and cytoplasmic regions of IL-12Rbeta1 or IL-12Rbeta2 were fused to the extracellular domain of the epidermal growth factor (EGF) receptor
Jane G Zapka et al.
American journal of preventive medicine, 23(1), 28-35 (2002-07-03)
Developing effective programs to promote colorectal cancer (CRC) screening requires understanding of the effect of healthcare system factors on access to screening and adherence to guidelines. This study assessed the role of insurance status, type of plan, the frequency of
C W van Eijk et al.
Medical progress through technology, 17(3-4), 243-247 (1991-01-01)
A detector has been developed for position sensitive registration of annihilation radiation. The 511 keV gamma rays are detected in a set of BaF2 scintillation crystals coupled to low pressure TMAE-filled photosensitive multi wire chambers. In a first experimental detector
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.