추천 제품
Quality Level
분석
98%
refractive index
n20/D 1.368 (lit.)
bp
104 °C (lit.)
density
1.666 g/mL at 25 °C (lit.)
SMILES string
Fc1c(F)c(F)c(c(F)c1F)C(F)(F)F
InChI
1S/C7F8/c8-2-1(7(13,14)15)3(9)5(11)6(12)4(2)10
InChI key
USPWUOFNOTUBAD-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 3
Flash Point (°F)
68.0 °F - closed cup
Flash Point (°C)
20 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
M H Baker et al.
Biomedical & environmental mass spectrometry, 16(1-12), 211-213 (1988-10-01)
The use of octafluorotoluene (OFT) as a versatile gas chromatographic/mass spectrometric derivatizing agent for steroids containing alcoholic, phenolic or alpha, beta-unsaturated keto functions, is described. Two distinct derivatizing schemes can be utilized, involving (method 1) a phase-transfer reaction, employing a
Naohide Shinohara et al.
International journal of environmental research and public health, 7(9), 3348-3358 (2010-10-16)
A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents' level of exposure, by placing the dosers of tracer gas at locations
Alexander V Belyakov et al.
The journal of physical chemistry. A, 124(49), 10216-10224 (2020-11-18)
The equilibrium molecular structure of the gaseous fluorofullerene C60F36 has been determined for the first time by the electron diffraction method with the use of quantum chemical calculations up to the RI-MP2/def2-TZVPP level of theory. Vibrational amplitudes and quadratic and
Z Fang et al.
Anesthesia and analgesia, 83(5), 1097-1104 (1996-11-01)
We examined the anesthetic and convulsant properties of 16 unfluorinated to completely fluorinated aromatic compounds, having six to nine carbon atoms (e.g., benzene to 1,3,5-tris(trifluoromethyl)benzene), and four cycloalkanes (cyclopentane to cyclooctane). Benzene, fluorobenzene, toluene, p-xylene, ethylbenzene, and cyclopentane caused excitation
LUMOS--A Sensitive and Reliable Optode System for Measuring Dissolved Oxygen in the Nanomolar Range.
Philipp Lehner et al.
PloS one, 10(6), e0128125-e0128125 (2015-06-02)
Most commercially available optical oxygen sensors target the measuring range of 300 to 2 μmol L-1. However these are not suitable for investigating the nanomolar range which is relevant for many important environmental situations. We therefore developed a miniaturized phase
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.