50484

Sigma-Aldrich

Methylene Blue solution

suitable for microbiology

동의어(들):

Ehrlich’s reagent III, Loeffler’s Methylene Blue

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C16H18ClN3S
CAS Number:
Molecular Weight:
319.85
Beilstein:
3641570
MDL number:
UNSPSC 코드:
12171500
PubChem Substance ID:
NACRES:
NA.47

유통기한

limited shelf life, expiry date on the label

농도

0.5% in H2O (0.5 g/100 mL)

기술

microbe id | staining: suitable

응용 분야

microbiology

적합성

Bacillus spp.
Corynebacterium spp.
bacteria

SMILES string

[Cl-].CN(C)c1ccc2N=C3C=C\C(C=C3Sc2c1)=[N+](/C)C

InChI

1S/C16H18N3S.ClH/c1-18(2)11-5-7-13-15(9-11)20-16-10-12(19(3)4)6-8-14(16)17-13;/h5-10H,1-4H3;1H/q+1;/p-1

InChI key

CXKWCBBOMKCUKX-UHFFFAOYSA-M

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Methylene Blue was earlier recognized as a good nuclear stain, the staining solutions are always either aged or alkalized, if not both. More importantly it is an excellent stain for ribonucleic acid, which is the important stainable constituent of bacterial bodies, of lymphocyte and hemoportoal cytoplasm, and of nerve cell tigroid granules. It can also be employed in capsule stain. The capsule stain begins as a negative stain leaving the organisms colorless. The capsule are clearly seen as halo surrounding the bacterial cell. Another staining procedure is performed with nigrosin (Cat. No. 43925).

성분

reagent contains:
methylene blue 0.5 g
distilled water 100 ml

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Marcel Gehrung et al.
Journal of biomedical optics, 24(12), 1-11 (2019-10-19)
Photoacoustic tomography (PAT) is intrinsically sensitive to blood oxygen saturation (sO2) in vivo. However, making accurate sO2 measurements without knowledge of tissue- and instrumentation-related correction factors is extremely challenging. We have developed a low-cost flow phantom to facilitate validation of
Nicolaas Lucius Gerlach et al.
Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons, 72(4), 666-671 (2014-02-01)
To establish the accuracy of cone-beam computed tomographic (CBCT) views in determining the position and diameter of the mandibular canal. Two freshly frozen cadaver heads, 1 dentate and 1 edentate, were used to acquire CBCT scans. Measurements on cross-sectional CBCT
Q R J G Tummers et al.
European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology, 40(7), 850-858 (2014-05-28)
Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast conserving surgery. Based on certain physicochemical similarities between Technetium((99m)Tc)-sestamibi (MIBI), an SPECT radiodiagnostic with a sensitivity of
Jonel Steffen et al.
The British journal of ophthalmology, 98(1), 13-15 (2013-10-26)
To evaluate the diagnostic accuracy of methylene blue used as a non-invasive in vivo stain to detect ocular surface squamous neoplasia (OSSN). A test validation study was performed according to Standards for the reporting of diagnostic accuracy studies (STARD) guidelines
Muhannad N Fadhel et al.
Journal of biomedical optics, 24(11), 1-8 (2019-11-11)
Solid tumors are typically supplied nutrients by a network of irregular blood vessels. By targeting these vascular networks, it might be possible to hinder cancer growth and metastasis. Vascular disrupting agents induce intertumoral hemorrhaging, making photoacoustic (PA) imaging well positioned

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.