추천 제품
Grade
certified reference material
Quality Level
제품 라인
TraceCERT®
grade
TraceCERT®
품질
in 10% nitric acid
구성
Ag, 10 mg/L
Al, 50 mg/L
B, 50 mg/L
Ba, 10 mg/L
Bi, 100 mg/L
Ca, 10 mg/L
Cd, 10 mg/L
Co, 10 mg/L
Cr, 50 mg/L
Cu, 10 mg/L
Fe, 10 mg/L
K, 100 mg/L
Li, 50 mg/L
Mg, 10 mg/L
Mn, 10 mg/L
Mo, 50 mg/L
Na, 50 mg/L
Ni, 50 mg/L
Pb, 100 mg/L
Sr, 10 mg/L
Tl, 50 mg/L
Zn, 10 mg/L
농도
in 10% HNO3
기술
ICP: suitable
응용 분야
industrial qc
pharmaceutical
형식
multi-component solution
일반 설명
This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at https://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
Download your certificate at https://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.
애플리케이션
Multielement standard solution 1 has been used in the analysis of pollutants like trace elements in water using total reflection x-ray fluorescence (TXRF) method and inductively coupled plasma mass spectrometry(ICP-MS).
제조 메모
For the preparation of this CRM only materials of highest purity were used.
기타 정보
For a complete product listing of our ICP and AAS range, including technical information and example certificates, please visit ICP & AAS standards website.
Detailed information on our complete workflow solutions for ICP-AAS can be found in our Brochure: High-Purity Chemicals for Inorganic Trace Analysis.
In our effort to be more sustainable, we′re going digital with COAs-download them directly from our website.
Detailed information on our complete workflow solutions for ICP-AAS can be found in our Brochure: High-Purity Chemicals for Inorganic Trace Analysis.
In our effort to be more sustainable, we′re going digital with COAs-download them directly from our website.
For a complete product listing of our TraceCERT range of CRMs for ICP and AAS, technical information and example certificates please visit our inorganic TraceCERT website
법적 정보
TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 2 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - Skin Sens. 1
보충제 위험성
Storage Class Code
8B - Non-combustible, corrosive hazardous materials
WGK
WGK 3
개인 보호 장비
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
The development of TXRF method and its application on the study of trace elements in water at SSRF
Wang.LL, et al.
Nucl. Instrum. Methods Phys. Res. Sect. B, 375, 49-55 (2016)
Haibo Wang et al.
PLoS biology, 17(6), e3000292-e3000292 (2019-06-11)
Despite the broad-spectrum antimicrobial activities of silver, its internal usage is restricted, owing to the toxicity. Strategies to enhance its efficacy are highly desirable but rely heavily on the understanding of its molecular mechanism of action. However, up to now
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.