콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

502138

Supelco

EPA 8270/Appendix IX Nitrosamines Mix

certified reference material, 2000 μg/mL each component in methanol

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12000000

Grade

certified reference material

Quality Level

Agency

EPA 8270

제품 라인

TraceCERT®

grade

TraceCERT®

CofA

current certificate can be downloaded

특징

standard type calibration

포장

ampule of 1 mL

농도

2000 μg/mL each component in methanol

기술

HPLC: suitable
gas chromatography (GC): suitable

응용 분야

environmental

형식

multi-component solution

저장 온도

-10 to -25°C

애플리케이션

EPA 8270/Appendix IX nitrosamines mix has been used as a standard solution in the determination of N-nitrosamine in water samples using gas chromatography coupled with mass spectrometry (GC-MS). It has also been used as a standard in the determination of nicotine and N-nitrosamines in indoor house dust using gas chromatography (GC).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

기타 정보

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

법적 정보

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

분석물

설명

    N-Nitrosodibutylamine
    N-Nitrosodiethylamine
    N-Nitrosodimethylamine
    N-Nitrosodiphenylamine
    N-Nitrosodi-n-propylamine
    N-Nitrosomethylethylamine
    Nitrosomorpholine
    1-Nitrosopiperidine
    1-Nitrosopyrrolidine
    모두 보기 (9)

픽토그램

FlameSkull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Carc. 1B - Flam. Liq. 2 - Skin Sens. 1 - STOT SE 1

표적 기관

Eyes,Central nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 3


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Determination of nicotine and N-nitrosamines in house dust by pressurized liquid extraction and comprehensive gas chromatography?Nitrogen chemiluminiscence detection
Ramirez N, et al.
Journal of Chromatography A, 1219, 180-187 (2012)
Joy Roasa et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 36(3), 396-404 (2019-02-08)
A method to detect volatile nitrosamines in meat samples was developed using headspace sampling by solid-phase microextraction (HS-SPME), with analysis by GC-MS. A 50/30 µm divinylbenzene/carboxen/polydimethylsiloxane fused silica fibre was selected to extract a total of nine volatile nitrosamines: N-nitrosodimethylamine, N-nitrosomethylethylamine
Wilson Beita-Sandí et al.
Chemosphere, 211, 1091-1097 (2018-09-19)
Cation exchange resins have proved to be efficient in removing precursors of N-nitrosodimethylamine (NDMA). NDMA is a probable human carcinogen with a calculated lifetime cancer risk of 10-6 at 0.7 ng/L in drinking water. This paper investigated the effect of pH and
Fully automated determination of N?nitrosamines in environmental waters by headspace solid?phase microextraction followed by GC?MS?MS
Llop A, et al.
Journal of Separation Science, 33, 3692-3700 (2010)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..