추천 제품
Grade
pharmaceutical primary standard
API family
warfarin
제조업체/상표
USP
mp
162-164 °C (lit.)
응용 분야
pharmaceutical (small molecule)
형식
neat
저장 온도
2-8°C
SMILES string
CC(=O)CC(c1ccccc1)C2=C(O)c3ccccc3OC2=O
InChI
1S/C19H16O4/c1-12(20)11-15(13-7-3-2-4-8-13)17-18(21)14-9-5-6-10-16(14)23-19(17)22/h2-10,15,21H,11H2,1H3
InChI key
PJVWKTKQMONHTI-UHFFFAOYSA-N
유전자 정보
human ... VKORC1(79001)
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
This product is provided as delivered and specified by the issuing Pharmacopoeia. All information provided in support of this product, including SDS and any product information leaflets have been developed and issued under the Authority of the issuing Pharmacopoeia.For further information and support please go to the website of the issuing Pharmacopoeia.
애플리케이션
Warfarin USP Reference standard, intended for use in specified quality tests and assays as specified in the USP compendia. Also, for use with USP monographs such as:
- Warfarin Sodium
- Warfarin Sodium Tablets
- Warfarin Sodium for Injection
분석 메모
These products are for test and assay use only. They are not meant for administration to humans or animals and cannot be used to diagnose, treat, or cure diseases of any kind.
기타 정보
Sales restrictions may apply.
법적 정보
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 1 Dermal - Acute Tox. 1 Inhalation - Acute Tox. 2 Oral - Aquatic Chronic 2 - Repr. 1A - STOT RE 1 Oral
표적 기관
Blood
Storage Class Code
6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Circulation, 131(5), 488-494 (2014-12-17)
Temporary interruption of oral anticoagulation for procedures is often required, and some propose using bridging anticoagulation. However, the use and outcomes of bridging during oral anticoagulation interruptions in clinical practice are unknown. The Outcomes Registry for Better Informed Treatment of
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 17(4), 308-314 (2014-07-23)
The aim of this study was to evaluate our clinical experience with the Jarvik 2000 axial flow pump (Jarvik Heart, Inc, New York, NY, USA), a miniature axial flow left ventricular assist device (LVAD). The clinical results of eight patients
Blood, 124(1), 142-150 (2014-05-02)
Pathologic blood clotting is a leading cause of morbidity and mortality in the developed world, underlying deep vein thrombosis, myocardial infarction, and stroke. Genetic predisposition to thrombosis is still poorly understood, and we hypothesize that there are many additional risk
The Lancet. Neurology, 14(4), 361-367 (2015-02-17)
Extracranial carotid and vertebral artery dissection is an important cause of stroke, especially in young people. In some observational studies it has been associated with a high risk of recurrent stroke. Both antiplatelet drugs and anticoagulant drugs are used to
Cardiovascular drugs and therapy, 28(6), 575-585 (2014-10-17)
This study aimed to evaluate the cost-effectiveness of dabigatran and rivaroxaban compared with warfarin for the prevention of stroke in patients with atrial fibrillation (AF) in Singapore. A Markov model was constructed to compare the lifetime costs, quality-adjusted life-years (QALYs)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.