MilliporeSigma
All Photos(1)

CDUFBI0A1

Milli-Q

Biopak® Polisher

Ultrafilter for the production of pyrogen-, nuclease-, protease- and bacteria-free water at the point of dispense of Milli-Q® IQ/IX/EQ systems

eCl@ss:
33050190

material

polysulfone filter

Quality Level

packaging

pkg of 1 unit

manufacturer/tradename

BioPak®

technique(s)

ELISA: suitable
PCR: suitable
cell culture | mammalian: suitable

compatibility

for use with Milli-Q® EQ 7000
for use with Milli-Q® EQ 7008
for use with Milli-Q® EQ 7016
for use with Milli-Q® IX 7003
for use with Milli-Q® IX 7005
for use with Milli-Q® IX 7010
for use with Milli-Q® IX 7015
for use with Milli-Q® IQ 7000
for use with Milli-Q® IQ 7003
for use with Milli-Q® IQ 7005
for use with Milli-Q® IQ 7010
for use with Milli-Q® IQ 7015

shipped in

ambient

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
CDUFBI001LCPAK00A1MPGPG02A1
Biopak® Polisher Ultrafilter for the production of pyrogen-, nuclease-, protease- and bacteria-free water at the point of dispense of Milli-Q® IQ/IX/EQ systems

Milli-Q

CDUFBI0A1

Biopak® Polisher

Biopak® Polisher Ultrafilter for the production of pyrogen-, nuclease-, and bacteria-free water

Milli-Q

CDUFBI001

Biopak® Polisher

LC-Pak® Polisher Placed at the point of dispense of Milli-Q® IQ/EQ 7 series water systems. Suitable for HPLC, UHPLC, LC-MS and LC-MS/MS analyses.

Milli-Q

LCPAK00A1

LC-Pak® Polisher

Millipak® Gold Filter For particulates- and bacteria-free water at the point of dispense of the Milli-Q® 7 series water purification systems.

Milli-Q

MPGPG02A1

Millipak® Gold Filter

manufacturer/tradename

BioPak®

manufacturer/tradename

BioPak®

manufacturer/tradename

-

manufacturer/tradename

Millipak®

compatibility

for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015

compatibility

for use with Direct-Q® UV, for use with Elix® Advantage, for use with Milli-Q® Direct, for use with Milli-Q® Reference, for use with Simplicity® UV, for use with Synergy® UV

compatibility

for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015

compatibility

for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015

material

polysulfone filter

material

polysulfone (Ultrafiltration Hollow Fibers)

material

cartridge (Reverse-phase C18 granular silica based cartridge)

material

polyethersulfone filter

technique(s)

ELISA: suitable

technique(s)

-

technique(s)

LC/MS: suitable, UHPLC: suitable

technique(s)

-

shipped in

ambient

shipped in

ambient

shipped in

ambient

shipped in

ambient

General description

The Biopak® Polisher is an ultrafiltration cartridge designed to produce water suitable for molecular biology, biochemistry and cell culture when fed with Milli-Q® purified water. It is validated for continuous use for 90 days.

Application

Biopak® Polisher ultrafiltration cartridge is suitable for use with Milli-Q® IX 7003/05/10/15, Milli-Q® IQ 7000, Milli-Q® IQ 7003/05/10/15, Milli-Q® EQ 7000 and Milli-Q® EQ 7008/16 water purification systems.. Designed for applications such as molecular biology, biochemistry and cell culture (when fed with Milli-Q® purified water), the Biopak® ultrafiltration unit removes macromolecules and larger biological structures, such as bacteria.

Biopak® Polisher is recommended for a wide range of laboratory applications where bacteria, pyrogen, nuclease and/or protease levels must be controlled.
This includes small-interfering RNA (siRNA) research, RNA in situ hybridization, microarray development, or studies of protein synthesis machinery.

Features and Benefits

  • Minimizes risk of nuclease, protease, pyrogen or bacteria contamination.
  • Eliminates the need for toxic agents such as DEPC, therefore improving safety, saving time and reducing costs.
  • Bottom-tip is redesigned for a secured installation of the protection bell.
  • Easy maintenance: the polisher is easily installed and replaced; does not require sanitization.
  • e-Sure tag for RFID connection with POD enables full traceability (data management) and automatic consumable status monitoring on the POD′s touchscreen interface.

Other Notes

  • Pyrogens (endotoxins) < 0.001 EU/mL
  • RNases < 1 pg/mL
  • DNases < 5 pg/mL
  • Protease < 0.15 μg/mL
  • Bacteria < 0.01 CFU/mL

Directions for Use

  • Organism Retention: Bacteria and pyrogens
  • Mode of Action: Ultrafiltration
  • Application: Cell culture media, molecular biology
  • Intended Use: Bioburden reduction
  • Instructions for Use: This item provides water filtered through ultrafiltration hollow fibers. Refer to insert, section "replacement" in the product package.
  • Storage Statement: Store in dry location.
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

BIOPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 5

1 of 5

Graphene oxide size and oxidation degree govern its supramolecular interactions with siRNA
Reina G, et al.
Nanoscale, 10(30), 5965-5974 (2018)
Giacomo Reina et al.
Nanoscale, 10(13), 5965-5974 (2018-03-16)
Several studies have demonstrated the ability of graphene oxide (GO) to efficiently adsorb small-interfering RNA (siRNA) on its surface and to transport it into cells. However, studies on whether and how siRNA interacts with GO are still inconclusive. In this
Detection and Quantification of MicroRNAs by Ligase-Assisted Sandwich Hybridization on a Microarray
Iizuka R, et al.
Microarrays, 1368 (2016)
Andrea Bleckmann et al.
Methods in molecular biology (Clifton, N.J.), 1669, 159-171 (2017-09-25)
A key element to understand developmental and reproductive processes like germline development, double fertilization, and embryogenesis is the study of cell-specific gene expression patterns which is best analyzed by RNA in situ hybridization. Different visualization techniques have been established to
Real-time assay for testing components of protein synthesis
Rosenblum G, et al.
Nucleic Acids Research, 40(12), e88-e88 (2012)

Articles

Nuclease-Free Water at Your Fingertips

An ultrafiltration cartridge can be placed at the outlet of a water purification system to deliver nuclease-free ultrapure water.

Ultrapure Water for BPA-free Culture Media in Embryology Research

Endocrine disruptors such as BPA can interfere with embryological development. This study shows ultrapure water from a Milli-Q® lab water system to be free of detectable BPA and thus suitable for embryology research.

Related Content

Water for Electrophysiology Studies

Freshly purified ultrapure water is recommended for electrophysiology assays. Using an ultrafiltration cartridge (Biopak®) at the of use of the water system eliminates risk of bacteria and endotoxin contamination that can negatively impact such techniques.

Milli-Q® Ultrapure Water Solutions

Always have confidence in your science with Milli-Q® ultrapure water. Discover our expanded system offer to find the lab water solution that fully satisfies your lab’s needs and constraints.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service