MilliporeSigma
All Photos(1)

Y0001209

Meglumine

European Pharmacopoeia (EP) Reference Standard

Sign Into View Organizational & Contract Pricing

Select a Size

Synonym(s):
N-Methyl-D-glucamine, 1-Deoxy-1-(methylamino)-D-glucitol, Meglumine
Empirical Formula (Hill Notation):
C7H17NO5
CAS Number:
Molecular Weight:
195.21
Beilstein:
385906
MDL number:
PubChem Substance ID:
NACRES:
NA.24

grade

pharmaceutical primary standard

API family

meglumine

autoignition temp.

~662 °F

manufacturer/tradename

EDQM

mp

129-131.5 °C (lit.)

application(s)

pharmaceutical (small molecule)

format

neat

storage temp.

2-8°C

SMILES string

CNC[C@H](O)[C@@H](O)[C@H](O)[C@H](O)CO

InChI

1S/C7H17NO5/c1-8-2-4(10)6(12)7(13)5(11)3-9/h4-13H,2-3H2,1H3/t4-,5+,6+,7+/m0/s1

Inchi Key

MBBZMMPHUWSWHV-BDVNFPICSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
PHR13241.061878.18318
Meglumine European Pharmacopoeia (EP) Reference Standard

Y0001209

Meglumine

Meglumine Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1324

Meglumine

Meglumine EMPROVE® EXPERT, Ph. Eur., ChP, JP, USP

SAFC

1.06187

Meglumine

manufacturer/tradename

EDQM

manufacturer/tradename

-

manufacturer/tradename

-

manufacturer/tradename

-

application(s)

pharmaceutical (small molecule)

application(s)

pharmaceutical (small molecule)

application(s)

liquid formulation
pharmaceutical
solid formulation
solubility enhancement

application(s)

-

format

neat

format

neat

format

-

format

-

API family

meglumine

API family

meglumine

API family

-

API family

-

autoignition temp.

~662 °F

autoignition temp.

~662 °F

autoignition temp.

~662 °F

autoignition temp.

~662 °F

General description

This product is provided as delivered and specified by the issuing Pharmacopoeia. All information provided in support of this product, including SDS and any product information leaflets have been developed and issued under the Authority of the issuing Pharmacopoeia.
For further information and support please go to the website of the issuing Pharmacopoeia.

Application

Meglumine EP Reference standard, intended for use in laboratory tests only as specifically prescribed in the European Pharmacopoeia.

Packaging

The product is delivered as supplied by the issuing Pharmacopoeia. For the current unit quantity, please visit the EDQM reference substance catalogue.

Other Notes

Sales restrictions may apply.

related product

Product No.
Description
Pricing

Storage Class Code

11 - Combustible Solids

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Lourens F H J Robbers et al.
Radiology, 272(1), 113-122 (2014-03-13)
To investigate the effects of cell therapy on myocardial perfusion recovery after treatment of acute myocardial infarction (MI) with primary percutaneous coronary intervention (PCI). In this HEBE trial substudy, which was approved by the institutional review board (trial registry number
Gilles Barone-Rochette et al.
Journal of magnetic resonance imaging : JMRI, 40(6), 1347-1354 (2013-12-03)
To determine the value of cardiac MRI for the monitoring and the prognosis of patients with acute myocarditis. Cardiac MRI plays an increasingly important role in the diagnosis of acute myocarditis. However, it is less established as a prognostic tool
Chong Hyun Suh et al.
Radiology, 272(2), 504-513 (2014-04-05)
To determine the utility of intravoxel incoherent motion (IVIM)-derived perfusion and diffusion parameters for differentiation of atypical primary central nervous system lymphoma (PCNSL) from glioblastoma in patients who do not have acquired immunodeficiency syndrome. The institutional review board approved this
Philipp Kickingereder et al.
Radiology, 272(3), 843-850 (2014-05-13)
To compare multiparametric diagnostic performance with diffusion-weighted, dynamic susceptibility-weighted contrast material-enhanced perfusion-weighted, and susceptibility-weighted magnetic resonance (MR) imaging for differentiating primary central nervous system lymphoma (PCNSL) and atypical glioblastoma. This retrospective study was institutional review board-approved and informed consent was
Suk Jae Kim et al.
Annals of neurology, 76(3), 356-369 (2014-07-06)
Dedicated magnetic resonance (MR) imaging (MRI) sequences for evaluation of collaterals can be generated using MR perfusion (MRP) source data. We compared a novel collateral flow imaging technique with digital subtraction angiography (DSA) for determining collateral circulation in acute stroke

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service