MilliporeSigma
All Photos(3)

575673-U

Supelco

HybridSPE®-PLus 96-Well Plate

volume 2 mL, pk of 20 ea

Synonym(s):
HybridSPE®-PLus
NACRES:
NB.21

description

96-well Plate

Quality Level

product line

HybridSPE®

composition

bed wt., 50 mg

packaging

pk of 20 ea

technique(s)

solid phase extraction (SPE): suitable

volume

2 mL

matrix active group

zirconia-based phase

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
575659-U57495-U57494-U
packaging

pk of 20 ea

packaging

pk of 1 ea

packaging

pk of 1 ea

packaging

pk of 1 ea

technique(s)

solid phase extraction (SPE): suitable

technique(s)

solid phase extraction (SPE): suitable

technique(s)

solid phase extraction (SPE): suitable

technique(s)

solid phase extraction (SPE): suitable

matrix active group

zirconia-based phase

matrix active group

zirconia-based phase

matrix active group

-

matrix active group

-

description

96-well Plate

description

96-well Plate

description

detection: MS friendly

description

detection: MS friendly

product line

HybridSPE®

product line

HybridSPE®

product line

-

product line

-

General description

HybridSPE-PLus is the next generation of HybridSPE-Phospholipid technology. The first of its kind, HybridSPE-Phospholipid technology was first introduced in 2008. It fuses the simple, standardized methodology of traditional protein precipitation with the specificity of solid phase extraction (SPE) for the simultaneous removal of proteins and phospholipids from biological samples prior to LC-MS analysis. Unlike other phospholipid removal products that use a hydrophobic retention mechanism to remove phsopholipids from biological samples, HybridSPE-Phospholipid technology uses a unique Lewis acid/base retention mechanism that allows it to separate phospholipids from even very hydrophobic analytes, such as vitamins, which are often retained along with phospholipids on competitive products.

Our HybridSPE-PLus products offer the same time-proven chemistry of our traditional HybridSPE-Phospholipid products coupled with manufacturing enhancements that stem from years of production experience. These manufacturing enhancements have allowed us to increase flow consistency and reduce sample hold up volumes, further improving analyte recoveries and assay reproducibility. We invite customers to take advantage of the newest technology; HybridSPE-PLus.

Features and Benefits

  • Simple 2-3 step standard methodology analogous to traditional protein precipitation provides simultaneous removal of both proteins and phospholipids
  • Unique Lewis acid/base retention mechanism effectively removes phospholipids from both hydrophilic and hydrophobic analytes of interest (unlike competitive chemistries) eliminating phospholipid-induced ion suppression
  • Highly reproducible, consistent product performance
  • Provides cleaner samples for longer column life and less instrument downtime
  • Available in 96-well and 1 mL cartridge dimensions

Legal Information

HybridSPE is a registered trademark of Sigma-Aldrich Co. LLC

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 1

1 of 1

Articles

Two Distinct Sample Prep Approaches to Overcome Matrix Effect in LC/MS of Serum or Plasma Samples

This article highlights the impact that sample matrix effects can have on LC/MS response and discusses two novel approaches to reduce it.

Protocols

Rapid, Sensitive, and Quantitative LC/MS/MS Determination of Digitoxin and Digoxin in Plasma

Immunoassay-based methods for digitoxin or digoxin exist, but are time consuming, labor intensive, and not selective due to similarities in their chemical structures.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service