コンテンツへスキップ
Merck

50811-U

Supelco

Ascentis® Express 90 Å C18 (2 μm) HPLC Columns

L × I.D. 5 cm × 2.1 mm UHPLC Column

別名:

コアシェル(SPP)融合コア C18 HPLC カラム

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41115700
NACRES:
SB.52

製品名

Ascentis® Express C18、2 μm UHPLCカラム, 2 μm particle size, L × I.D. 5 cm × 2.1 mm

物質

stainless steel column

品質水準

認証

suitable for USP L1

製品種目

Ascentis®

特徴

endcapped

メーカー/製品名

Ascentis®

包装

1 ea of

パラメーター

1000 bar max. pressure (14500 psi)
60 °C temp. range

テクニック

LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

L × 内径

5 cm × 2.1 mm

表面積

120 m2/g

不純物

<5 ppm metals

Matrix

Fused-Core particle platform
superficially porous particle

マトリックス活性基

C18 (octadecyl) phase

粒径

2 μm

ポアサイズ

90 Å pore size

使用pH

2-9

アプリケーション

food and beverages

分離法

reversed phase

類似した製品をお探しですか? 訪問 製品比較ガイド

おすすめ製品

HPLCあるいはLC-MS分析に理想的なリクロピュア試薬が見つかります

法的情報

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

この製品を見ている人はこちらもチェック

Silvia Jakabová et al.
Journal of chromatography. A, 1232, 295-301 (2012-03-07)
Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in the Datura genus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a
Heena et al.
Journal of chromatographic science, 53(5), 800-806 (2014-10-18)
This study represents a new analytical high-performance liquid chromatography-fluorescence detector method for the determination of Al(III) as Al(III) complex with 8-hydroxyquinoline-5-sulfonic acid in a tap water sample and a coke sample. A micellar liquid chromatographic method is proposed for the
Pankaj Partani et al.
Journal of chromatographic science, 54(8), 1385-1396 (2016-05-27)
A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of simvastatin (SV) and simvastatin acid (SVA) in human plasma. To improve assay sensitivity and achieve simultaneous analysis, SVA monitored in (-)ESI (electrospray ionization) mode within
Petra Šilarová et al.
Food chemistry, 237, 471-480 (2017-08-03)
The degradation of catechins and other phenolics in green tea infusions were monitored using fast HPLC/MS separation. The final separation was performed within 2.5min using Ascentis Express C18 column (50mm×2.1mm i.d.) packed with 2μm porous shell particles. Degradation was studied
Judy Stone
Methods in molecular biology (Clifton, N.J.), 1378, 301-320 (2015-11-26)
Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 %

関連コンテンツ

Small molecules are ions and compounds of molecular weight typically less than 900 daltons. These compounds can be effectively separated and analyzed by HPLC, UHPLC and LC-MS using mainly silica particles or monolithic stationary phases with a broad range of column chemistries (modifications).

低分子とは、通常、分子量900ダルトン未満のイオンおよび化合物を指します。これらの化合物は、さまざまな化学的性質(修飾)を有するシリカ粒子またはモノリス型の固定相を主に用いるHPLC、UHPLCおよびLC-MSを用いて、効率よく分離することが可能です。

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)