콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

M-153

Supelco

Methotrexate-D3 solution

100 μg/mL in methanol with 0.01N NaOH, ampule of 1 mL, certified reference material, Cerilliant®

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C20H19N8O5D3
CAS Number:
Molecular Weight:
457.46
EC Number:
UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

certified reference material

Quality Level

양식

liquid

특징

Snap-N-Spike®/Snap-N-Shoot®

포장

ampule of 1 mL

제조업체/상표

Cerilliant®

농도

100 μg/mL in methanol with 0.01N NaOH

기술

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

응용 분야

pharmaceutical (small molecule)

형식

single component solution

저장 온도

−20°C

SMILES string

[2H]C([2H])([2H])N(Cc1cnc2nc(N)nc(N)c2n1)c3ccc(cc3)C(=O)NC(CCC(O)=O)C(O)=O

InChI

1S/C20H22N8O5/c1-28(9-11-8-23-17-15(24-11)16(21)26-20(22)27-17)12-4-2-10(3-5-12)18(31)25-13(19(32)33)6-7-14(29)30/h2-5,8,13H,6-7,9H2,1H3,(H,25,31)(H,29,30)(H,32,33)(H4,21,22,23,26,27)/i1D3

InChI key

FBOZXECLQNJBKD-FIBGUPNXSA-N

일반 설명

An internal standard suitable for therapeutic drug monitoring analyses of methotrexate patient serum samples by LC-MS/MS. Used in the treatment of cancer and autoimmune diseases, methotrexate is an antimetabolite and antifolate drug monitored by clinical labs to ensure patients remain within the drug′s therapeutic range. The Snap-N-Spike® solution format allows laboratories to eliminate weighing operations of hazardous substances such as methotrexate, significantly reducing occupational exposure hazards related to handling of acutely toxic powders, and provides the ability to spike into their matrix of choice just before use.

법적 정보

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - Met. Corr. 1 - STOT SE 1

표적 기관

Eyes,Central nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

49.5 °F - closed cup

Flash Point (°C)

9.7 °C - closed cup


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Matthew Jeronimo et al.
Analytical and bioanalytical chemistry, 407(23), 7083-7092 (2015-07-05)
An effective wipe sampling and LC-MS/MS method was developed to simultaneously analyze six commonly administered antineoplastic drugs in stainless steel surface. The analyzed drugs were methotrexate, paclitaxel, cyclophosphamide, 5-fluorouracil, vincristine, and oxaliplatin, a frequently prepared antineoplastic drug that has not

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.