추천 제품
Quality Level
분석
≥70% (HPLC)
형태
powder
mp
>300 °C (lit.)
λmax
596 nm
εmax
≥20000 at 253-259 nm in water at 0.01 g/L
≥23000 at 224-230 nm in water at 0.01 g/L
응용 분야
diagnostic assay manufacturing
hematology
histology
저장 온도
room temp
SMILES string
[Na+].Nc1c2C(=O)c3ccccc3C(=O)c2c(Nc4cccc(c4)S(=O)(=O)C=C)cc1S([O-])(=O)=O
InChI
1S/C22H16N2O7S2.Na/c1-2-32(27,28)13-7-5-6-12(10-13)24-16-11-17(33(29,30)31)20(23)19-18(16)21(25)14-8-3-4-9-15(14)22(19)26;/h2-11,24H,1,23H2,(H,29,30,31);/q;+1/p-1
InChI key
ANOULJGZTVOIFB-UHFFFAOYSA-M
애플리케이션
Reactive stain for proteins
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Acute Tox. 4 Oral
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
British journal of pharmacology, 115(3), 427-432 (1995-06-01)
1. Using a grease-gap recording technique we have investigated the effects of some antagonists of P2-purinoceptors on the depolarization of the rat isolated superior cervical ganglion evoked by 100 microM alpha, beta-methylene-adenosine 5'-triphosphate (alpha,beta-MeATP) or uridine 5'-triphosphate (UTP). The effects
PloS one, 7(2), e31438-e31438 (2012-03-01)
The identification of proteins by mass spectrometry is a standard method in biopharmaceutical quality control and biochemical research. Prior to identification by mass spectrometry, proteins are usually pre-separated by electrophoresis. However, current protein staining and de-staining protocols are tedious and
Naunyn-Schmiedeberg's archives of pharmacology, 359(4), 339-344 (1999-05-27)
In order to assess the consequences of a concomitant blockade of P2X-receptors and ecto-nucleotidases, effects of 13 P2-receptor antagonists were investigated on contractions of the rat vas deferens elicited by alpha,beta-methylene ATP (alpha,beta-MeATP) and ATP and on the removal of
Rapid communications in mass spectrometry : RCM, 25(13), 1801-1811 (2011-06-04)
The structural elucidation of carbonyl-containing by-products arising from Uniblu-OH ozonation has been investigated by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) employing a quadrupole time-of-flight mass spectrometer. The by-products were derivatized with 2,4-dinitrophenylhydrazine, allowing the formation of [M-H](-) ions of
Catalytic decomposition of the reactive dye Uniblue A on hematite. Modeling of the reactive surface.
Water research, 35(3), 750-760 (2001-03-07)
Experimental results from the adsorption and subsequent catalytic combustion of the reactive dye Uniblue A on hematite indicate that this iron oxide can be used as an affordable catalyst for environmental purposes. Uniblue A was adsorbed on hematite and the
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.