콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

MAK124

Sigma-Aldrich

BCG Albumin Assay Kit

sufficient for 250 colorimetric tests

동의어(들):

Bromocresol Green Albumin Assay

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12161503
NACRES:
NA.84

사용

sufficient for 250 colorimetric tests

검출 방법

colorimetric

관련 질환(들)

genitourinary disorders; gastrointestinal diseases

저장 온도

−20°C

유전자 정보

human ... ALB(213)
mouse ... ALB(11657)
rat ... ALB(24186)

일반 설명

Albumin is the most abundant plasma protein in humans. It accounts for ∼60% of the total serum protein. Albumin plays important physiological roles, including maintenance of colloid osmotic pressure and binding of key substances such as long-chain fatty acids, bile acids, bilirubin, hematin, calcium, and magnesium. It has antioxidant and anticoagulant effects, acts as a carrier for nutritional factors and drugs, and is an effective plasma pH buffer. Serum albumin is a reliable prognostic indicator for morbidity and mortality, liver disease, nephritic syndrome, malnutrition, and protein-losing enteropathies. High levels are associated with dehydration.

애플리케이션


  • LncRNA ZEB1-AS1 inhibits renal fibrosis in diabetic nephropathy by regulating the miR-217/MAFB axis.: This research utilizes the BCG Albumin Assay Kit to quantitatively analyze albumin levels in studies of diabetic nephropathy. The results demonstrate the regulatory role of lncRNA on miR-217/MAFB axis, contributing significantly to the understanding and potential treatments of kidney fibrosis in diabetic patients (Song et al., 2019).

  • Albumin depletion of human plasma also removes low abundance proteins including the cytokines.: This study employs the BCG Albumin Assay Kit to investigate the effects of albumin depletion in human plasma, specifically its impact on the presence of low abundance proteins such as cytokines. The findings are crucial for the refinement of proteomic analyses and understanding protein interactions in biological samples (Granger et al., 2005).


특징 및 장점

Compatible with high-throughput handling systems. Can be adapted for use with cuvettes.

적합성

Suitable for the detection of Albumin in serum, plasma, urine, and other biological samples.

원리

The BCG (Bromocresol Green) albumin assay kit is designed to measure albumin directly without any pretreatment of samples. The optimized formulation substantially reduces interference by other substances (lipids/other proteins) in the raw samples. It may also be used to measure effects of drugs and other compounds on albumin metabolism. The procedure involves addition of a single working reagent and a 5 minute incubation. The optimized formulation has greatly enhanced reagent and signal stability. The kit utilizes bromocresol green, which forms a colored complex specifically with albumin. The intensity of the color, measured at 620 nm, is directly proportional to the albumin concentration in the sample.

Storage Class Code

12 - Non Combustible Liquids

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Slide 1 of 1

1 of 1

Marvin Gonzalez-Quiroz et al.
BMC nephrology, 20(1), 21-21 (2019-01-18)
After two-years of follow-up of 263 apparently healthy 18- to 30-year-old men in communities affected by Mesoamerican nephropathy (MeN), we identified three distinct case groups: a subgroup with (i) established renal dysfunction (case-group 1); individuals with (ii) a rapid decline in
Alaa T Alshareeda et al.
PloS one, 12(8), e0184004-e0184004 (2017-08-30)
Hepatocellular carcinoma (HCC) is considered the 3rd leading cause of death by cancer worldwide with the majority of patients were diagnosed in the late stages. Currently, there is no effective therapy. The selection of an animal model that mimics human
Maria Callejo et al.
Journal of clinical medicine, 9(2) (2020-02-12)
Introduction: Epidemiological studies suggest a relationship between vitamin D deficiency and cardiovascular and respiratory diseases. However, whether total, bioavailable, and/or free vitamin D levels have a prognostic role in pulmonary arterial hypertension (PAH) is unknown. We aimed to determine total
Yin-Ting Yeh et al.
Scientific reports, 8(1), 13623-13623 (2018-09-13)
Blood is a complex fluid consisting of cells and plasma. Plasma contains key biomarkers essential for disease diagnosis and therapeutic monitoring. Thus, by separating plasma from the blood, it is possible to analyze these biomarkers. Conventional methods for plasma extraction
Gillian E Conway et al.
Mutagenesis, 35(4), 319-330 (2020-08-12)
Following advancements in the field of genotoxicology, it has become widely accepted that 3D models are not only more physiologically relevant but also have the capacity to elucidate more complex biological processes that standard 2D monocultures are unable to. Whilst

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.