コンテンツへスキップ
Merck
  • Development and validation of a dynamic range-extended LC-MS/MS multi-analyte method for 11 different postmortem matrices for redistribution studies applying solvent calibration and additional (13)C isotope monitoring.

Development and validation of a dynamic range-extended LC-MS/MS multi-analyte method for 11 different postmortem matrices for redistribution studies applying solvent calibration and additional (13)C isotope monitoring.

Analytical and bioanalytical chemistry (2015-09-24)
Sandra N Staeheli, Michael Poetzsch, Thomas Kraemer, Andrea E Steuer
要旨

Postmortem redistribution (PMR) is one of numerous problems in postmortem toxicology making correct interpretation of measured drug concentrations difficult or even impossible. Time-dependent PMR in peripheral blood and especially in tissue samples is still under-explored. For further investigation, an easy applicable method for the simultaneous quantitation of over 80 forensically relevant compounds in 11 different postmortem matrices should be developed and validated overcoming the challenges of high inter-matrix and intra-matrix concentration variances. Biopsy samples (20 mg) or body fluids (20 μL) were spiked with an analyte mix and deuterated internal standards, extracted by liquid-liquid extraction, and analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS). For highest applicability, an easy solvent calibration was used. Furthermore, time-consuming dilution of high concentration samples showing detector saturation was circumvented by two overlapping calibration curves using (12)C isotope monitoring for low concentrations and (13)C isotopes for high concentration, respectively. The method was validated according to international guidelines with modifications. Matrix effects and extraction efficiency were strongly matrix and analyte dependent. In general, brain and adipose tissue produced the highest matrix effects, whereas cerebrospinal fluid showed the least matrix effects. Accuracy and precision results were rather matrix independent with some exceptions. Despite using an external solvent calibration, the accuracy requirements were fulfilled for 66 to 81 % of the 83 analytes. Depending on the matrix, 75-93 % of the analytes showed intra-day precisions at <20 %. (12)C and (13)C calibrations gave comparable results and proved to be a useful tool in expanding the dynamic range.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
アセタール, ≥98%, FG
Supelco
クロナゼパム 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
アセトニトリル, ReagentPlus®, 99%
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
アセトニトリル, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
アセタール, natural, ≥97%, FG
Sigma-Aldrich
ゾルピデム, ≥98% (HPLC), solid
Sigma-Aldrich
アセトニトリル, ≥99.8%, suitable for HPLC
Sigma-Aldrich
クロナゼパム, powder
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
ゾピクロン
Sigma-Aldrich
アセトニトリル, JIS special grade, ≥99.5%
Sigma-Aldrich
アセトニトリル, ≥99.5%, ACS reagent
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
アセトニトリル, SAJ first grade, ≥99.0%
Sigma-Aldrich
アセトニトリル, for chromatography
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
アセトニトリル, for residue analysis, JIS 5000
Sigma-Aldrich
アセトニトリル 溶液, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
アセトニトリル 溶液, contains 0.05 % (v/v) trifluoroacetic acid