material
clear glass vial
round bottom
특징
closure type screw top vial
포장
pkg of 100 ea
O.D. × H
22.5 mm × 75.5 mm
용적
20 mL
피팅
thread for 18
호환성
for use with CTC PAL (Varian, Gerstel, Atas, Shimadzu)
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
These vials require a special cap with an 18 mm thread. The standard 18-400 threaded caps will not fit this vial. The part numbers for caps that are available for these vials are SU860101(with PTFE/silicone, 1.3 mm thick), SU860102 (with PTFE/butyl, 1.6 mm thick), and SU860103 (with PTFE/silicone, 1.5 mm thick). These caps are made from stainless steel and are magnetic.
애플리케이션
Headspace vial may be used for the following:
- In the determination of partition coefficient of ethyl acetate in water at 0° C from independent analyses of the total amount of ethyl acetate present in the vial, by automatic equilibrium headspace gas chromatography and vapor phase calibration (VPC).
- It may be used in the analysis of volatile polar residual solvents present in pharmaceutical products, during development and optimisation of headspace SPME method by GC-MS.
- It may also be used in the isotopic analysis of 18O in the leaf water of C3 and C4 grasses, during establishing a grassland signature in veins, as it was found that grasses with different photosynthetic pathway have different interveinal differences.
- It may also find application, in investigating metabolism by Pseudomonas fluorescens of volatile haloaliphatic hydrocarbons like 1,2-dichloroethane and 1,2-dichloropropane, which are some of the major contaminants of underground aquifers.
관련 제품
제품 번호
설명
가격
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Determination of partition coefficients by automatic equilibrium headspace gas chromatography by vapor phase calibration.
Welter KBC and Bichler C.
Chromatographia, 34 (5-8), 235-240 (1992)
B R Helliker et al.
Proceedings of the National Academy of Sciences of the United States of America, 97(14), 7894-7898 (2000-07-08)
We show that 18O evaporative enrichment of bulk leaf water in grass species can be significantly more enriched than predicted by the Craig-Gordon model, with C4 grasses considerably more enriched than C3 grasses. Our results suggest that the unanticipated 18O
P A Vandenbergh et al.
Applied and environmental microbiology, 54(10), 2578-2579 (1988-10-01)
A Pseudomonas fluorescens strain designated PFL12 was isolated from soil and water that were contaminated with various chloroaliphatic hydrocarbons. The isolate was able to metabolize 1,2-dichloroethane, 1,1,2-trichloroethane, 1,2-dichloropropane, 2,2-dichloropropane, and trichloroethylene.
C C Camarasu
Journal of pharmaceutical and biomedical analysis, 23(1), 197-210 (2000-07-18)
A solid-phase microextraction (SPME) method has been developed and optimized for the polar residual solvent determination in pharmaceutical products. Five different polymer-coated fibers were investigated and the Carboxen/polydimethylsiloxane was found to be the most sensitive for all components. Two Headspace
프로토콜
물에 함유된 VOC의 측정을 위해 GC/MS와 조합한 HS-SPME의 고성능, 신뢰성 및 재현성은 실험실간 시험에서 입증되었습니다. HS-SPME를 이용한 새로운 ISO 17943은 민감도와 선택성에서 이 측정의 기존 공식 방법을 개선하였습니다.
High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.