MilliporeSigma
All Photos(2)

Documents

GE29-0486-31

HisTrap Fast Flow Crude

Cytiva 29-0486-31, pack of 1 mL

NACRES:
NA.56

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

packaging

pack of 1 mL

manufacturer/tradename

Cytiva 29-0486-31

availability

not available in North America

parameter

<4 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.)
42 psi (H2O at room temperature.)

bed size

7 mm × 25 mm

bed volume

1 mL

column I.D.

7 mm

matrix

6% cross-linked agarose

particle size

45-165 μm

average diameter

90 μm

cleaning

2-14(Ni2+-stripped medium.)

working range

3-12(Ni2+-stripped medium.)

capacity

~40 mg binding capacity (histidine-tagged protein/ml medium)(Protein binding capacity is protein-to-protein dependent.)
~40 mg binding capacity(histidine-tagged protein)

suitability

suitable for bioprocess medium

Looking for similar products? Visit Product Comparison Guide

Related Categories

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
GE17-5286-01GE17-5255-01GE17-5319-01
HisTrap&#8482; Fast Flow Crude Cytiva 29-0486-31, pack of 1&#160;mL

GE29-0486-31

HisTrap Fast Flow Crude

HisTrap&#8482; Fast Flow Crude Cytiva 17-5286-01, pack of 5 × 5&#160;mL

GE17-5286-01

HisTrap Fast Flow Crude

HisTrap&#8482; Fast Flow Cytiva 17-5255-01, pack of 5 × 5&#160;mL

GE17-5255-01

HisTrap Fast Flow

HisTrap&#8482; Fast Flow Cytiva 17-5319-01, pack of 5 × 1&#160;mL

GE17-5319-01

HisTrap Fast Flow

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

shelf life

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

manufacturer/tradename

Cytiva 29-0486-31

manufacturer/tradename

Cytiva 17-5286-01

manufacturer/tradename

Cytiva 17-5255-01

manufacturer/tradename

Cytiva 17-5319-01

availability

not available in North America

availability

-

availability

-

availability

-

parameter

<4 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.)

parameter

<20 mL/min flow rate, 42 psi (H2O at room temperature.)

parameter

<4 mL/min flow rate (The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.), 42 psi

parameter

<20 mL/min flow rate, 42 psi

bed size

7 mm × 25 mm

bed size

16 mm × 25 mm

bed size

7 mm × 25 mm

bed size

16 mm × 25 mm

General description

HisTrap FF crude columns offer the convenience of simple, one-step purification of histidine-tagged proteins directly from homogenized, unclarified cell lysate by immobilized metal ion affinity chromatography (IMAC).

Application

HisTrap FF crude is a ready-to-use column, prepacked with precharged Ni Sepharose 6 Fast Flow. This prepacked column is intended for purification of histidine-tagged recombinant proteins by immobilized metal affinity chromatography (IMAC). After thorough cell disruption, it is possible to load the unclarified lysate on the column without precentrifugation and filtration of the sample. Extending the duration of the mechanical treatment of the sample to ensure a more complete lysis is recommended. For optimal results, we recommend first addition of lysozyme and DNase I followed by a mechanical lysis, for example by sonication. The homogenized sample can then be loaded directly on the column without a clarification step which may prevent degradation of the target protein and increase the activity.

Features and Benefits

  • Optimized for purification of histidine-tagged proteins directly from homogenized, unclarified cell lysates.
  • High binding capacity, approx. 40 mg/ml medium and negligible Ni2+ leakage
  • Compatible with a wide range of reducing agents, detergents, denaturants, and other additives.
  • Reduced sample preparation time, which minimizes risk of protein degradation by proteases.
  • No need for centrifugation or filtration of the samples. Direct sample application.
  • Reliable purification of histidine-tagged proteins directly from unclarified lysates–simply sonicate and run.
  • Reduced sample preparation time, which minimizes risk of protein degradation by proteases
  • Simple operation with a syringe, pump, or chromatography system such as ÄKTAdesign or FPLC System
  • Permit rapid yet reliable separations with a minimum of sample preparation and equipment

Storage and Stability

Store at 4 to 30 °C (20% Ethanol)

Legal Information

HisTrap is a trademark of Cytiva

Pictograms

Environment

Signal Word

Warning

Hazard Statements

Storage Class Code

3 - Flammable liquids


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 3

1 of 3

HiTrap&#174; TALON&#174; Crude Cytiva 28-9537-66, pack of 5 × 1&#160;mL

GE28-9537-66

HiTrap® TALON® Crude

HiTrap&#174; TALON&#174; Crude Cytiva 28-9537-67, pack of 5 × 5&#160;mL

GE28-9537-67

HiTrap® TALON® Crude

HisTrap&#8482; High Performance Cytiva 17-5248-02, pack of 5 × 5&#160;mL

GE17-5248-02

HisTrap High Performance

Articles

Performing a Purification and On-column Refolding of an Insoluble Histidine-tagged Protein

This page shows how to perform a purification and on-column refolding of an insoluble his-tagged protein from an E. coli culture with HisTrap™ FF columns and ÄKTAprime from Cytiva.

Performing a Cell Lysis of Recombinant Histidine-Tagged Proteins

For optimal conditions for growth, induction, and cell lysis of recombinant histidine-tagged proteins, please refer to established procedures. The following is a general procedure for cell lysis and sample preparation from bacterial cultures. Other established procedures may also work.

Protocols

Manual Purification Using HisTrap FF Crude Kit with a Syringe

HisTrap™ FF crude Kit is designed for rapid and convenient manual purification of histidine-tagged proteins using premade buffers and a syringe. Histidine-tagged proteins can be purified directly from unclarified cell lysates. This saves time because the pretreatment of the sample is minimized.

Affinity Chromatography in a Purification Strategy (CIPP)

This page shows the purification strategy of capture, intermediate purification, and polishing (CIPP) in affinity chromatography using Cytiva products.

Purification of Histidine-Tagged Proteins Secreted into Eukaryotic Cell Culture Supernatants Using HisTrap™ Excel

This page shows how to purify histidine-tagged proteins secreted into eukaryotic cell culture supernatants using HisTrap Excel from Cytiva.

Purification from Unclarified Cell Lysate using HisTrap™ FF Crude

This page shows how to purify histidine-tagged recombinant proteins from unclarified cell lysate using HisTrap FF crude from Cytiva.

See All

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service