おすすめの製品
品質水準
アッセイ
98%
mp
100-105 °C (lit.)
SMILES記法
OCNC(=O)CCl
InChI
1S/C3H6ClNO2/c4-1-3(7)5-2-6/h6H,1-2H2,(H,5,7)
InChI Key
TXNSZCSYBXHETP-UHFFFAOYSA-N
関連するカテゴリー
詳細
2-Chloro-N-(hydroxymethyl)acetamide (N-methylolchloracetamide) is a N-hydroxymethyl derivative of chloroacetamide. One of the method reported for its synthesis is by the reaction of 2-chloracetamide with formaldehyde. It has been reported to be a formaldehyde releaser and an infrequent sensitizer to formaldehyde contact allergy. Influence of short and prolonged exposure of 2-chloro-N-(hydroxymethyl)acetamide (as formaldehyde donor/releaser) on lymph node responses has been investigated.
アプリケーション
2-Chloro-N-(hydroxymethyl)acetamide (N-hydroxymethylchloroacetamide) may be used as a reagent in the synthesis of 1-(aminomethyl)-2-methoxynaphthalene hydrochloride and as a amidomethylating reagent for N,N-dialkylanilines (Tscherniac-Einhorn reaction).
シグナルワード
Danger
危険有害性情報
危険有害性の分類
Eye Dam. 1 - Skin Corr. 1B
保管分類コード
8A - Combustible corrosive hazardous materials
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
個人用保護具 (PPE)
Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
422835-1G:
422835-5G:
422835-BULK:
422835-VAR:
422835-25G:
Occupational contact dermatitis to N-methylol-chloracetamide.
Contact dermatitis, 17(3), 182-184 (1987-09-01)
Journal of immunotoxicology, 4(3), 239-246 (2008-10-30)
In the Local Lymph Node Assay (LLNA), a stimulation index of 3 (SI = 3) is established as a threshold value for hazard identification of sensitization. The corresponding EC3 value, the effective concentration inducing a threefold increase compared to controls
Allergic contact dermatitis from the preservative N-methylol-chloracetamide.
Contact dermatitis, 6(4), 302-303 (1980-06-01)
Mutation research, 156(1-2), 19-32 (1985-04-01)
The industrial biocide chloracetamide-N-metholol (CAM) has been shown to be non-mutagenic to 6 strains of Salmonella using both the plate-incorporation and a pre-incubation test protocol. Its biocidal activity is unlikely to have influenced these results since Kathon 886, a more
Contact dermatitis, 63(3), 129-139 (2010-06-25)
We have reviewed formaldehyde-releasers used in metalworking fluids (MWFs) in this and a previous part of a two-part article. These biocides do not appear to be frequent or important sensitizers. Even in highly selected patient groups of metalworkers, mean prevalence
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)