ORBO 23 2-HMP -Amberlite XAD®-2 (20/40), 120/60 mg

W,W,W separators, O.D. × L 6 mm × 85 mm, pkg of 25 ea

別名:

ORBO 2-HMP on Supelpak 20N Tube

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12190000
NACRES:
NB.24

物質

W,W,W separators

品質水準

認証

NIOSH 2501,2529,2536,2539,2541

製品種目

Amberlite
ORBO

組成

Bed A, 120 mg
Bed B, 60 mg

包装

pkg of 25 ea

メーカー/製品名

ORBO 23

テクニック

active air sampling: suitable

外径 × L

6 mm × 85 mm

Matrix

XAD-2 2-(Hydroxymethyl)piperidine on XAD-2

粒径

20-40 mesh

アプリケーション

air monitoring
environmental
industrial hygiene

保管温度

2-8°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

ORBO 23 2-HMP on Amberlite XAD®-2 (20/40), 120/60 mg sorbent tubes (W,W,W separators, O.D. × L 6 mm × 85 mm) contain two beds of the same selective adsorbent separated by glass wool or foam, for gas and vapor sampling. The dual-layer or two-bed construction of the tube allows for any sample breakthrough to be captured in the smaller back-up bed.

法的情報

Amberlite is a trademark of DuPont de Nemours, Inc.
ORBO is a trademark of Sigma-Aldrich Co. LLC
Supelpak is a trademark of Sigma-Aldrich Co. LLC
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

適切な製品が見つかりませんか。  

製品選択ツール.をお試しください

ピクトグラム

Corrosion

シグナルワード

Danger

危険有害性情報

危険有害性の分類

Eye Dam. 1 - Skin Corr. 1B

保管分類コード

8A - Combustible corrosive hazardous materials

WGK

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

20257-U:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

申し訳ございませんが、現在この製品のCOAをオンラインで入手できません。

サポートが必要な場合は、お問い合わせください カスタマーサポート

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

F J Egea González et al.
Journal of AOAC International, 80(5), 1091-1097 (1997-11-05)
A method to sample and analyze chlorothalonil and dichlofluanid in greenhouse air was evaluated. Analysis was performed by gas chromatography with electron capture detection and gas chromatography-mass spectrometry. Solid sorbents such as Chromosorb 102, Porapak R, Supelpak-2, Amberlite XAD-2, Amberlite
Bjørn T Moe et al.
Anticancer research, 29(4), 1047-1052 (2009-05-06)
Endometrial hyperplasia is a precursor lesion of endometrial carcinoma. Clinical studies of endometrial hyperplasia have shown that levonorgestrel (LNG) is more therapeutically effective than medroxyprogesterone acetate (MPA). The present pharmacological in vitro study was performed to compare progestin effects on
K Flo et al.
Scandinavian journal of clinical and laboratory investigation, 55(8), 715-721 (1995-12-01)
Elevated extracellular cGMP levels have been observed in various clinical conditions, and the analyte has been proposed as a diagnostic marker of cardiovascular as well as malignant diseases. However, the use of extracellular cGMP as a pathophysiological marker requires detailed
A Orbo et al.
Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke, 117(7), 972-976 (1997-03-10)
The development of female steroid hormone-related neoplasms such as gynaecologic and mammary cancers is influenced by hormones administered exogenously. Hormonal contraceptives and hormone replacement therapy both affect the risk of developing cancers in the endometrium, cervix, ovarium, and mammary glands.
H Stalsberg et al.
Virchows Archiv. A, Pathological anatomy and histopathology, 414(5), 415-422 (1989-01-01)
The autopsies of 12 victims from two snow avalanches in North-Norway are reported. Supportive evidence from non-autopsied and surviving victims is included. Consistent autopsy findings were prominent lung oedema, moderate cerebral oedema, extreme contraction of the left ventricle, petechiae in

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)