コンテンツへスキップ
Merck

2-Methoxy-3-isobutylpyrazine in grape berries and its dependence on genotype.

Phytochemistry (2010-10-23)
Alfredo Koch, Carolyn L Doyle, Mark A Matthews, Larry E Williams, Susan E Ebeler
要旨

2-Methoxy-3-isobutylpyrazine (MIBP) contributes a bell pepper aroma to many grape cultivars and has a reported aroma threshold of ∼2 ng L(-1) in water. The purpose of this study was twofold: (1) develop a procedure using headspace solid phase micro-extraction combined with GC-MS in the selected ion monitoring mode (HS-SPME-GC-MS-SIM) for analysis of MIBP in grape berries, and (2) determine the location of MIBP biosynthesis in grapevines by approach grafting clusters of Vitis vinifera L. cvs Cabernet Sauvignon and Muscat blanc onto each other. The soluble solids and pH of the grape juice/homogenate matrix from different grape berry developmental stages influenced the method precision; therefore, quantification via the method of standard addition was used. Using our developed method, the limit of detection (LOD) and limit of quantitation (LOQ) of MIBP were 0.1 ng L(-1) and 2 ng L(-1), respectively, measured in a model juice and non-MIBP containing Chardonnay juice. Spiked recoveries averaged between 91% and 112% in Cabernet Sauvignon and Pinot noir homogenates and the overall relative standard deviation was less than 10%. The method was used to analyze MIBP in 29 grape cultivars and in fruit from clusters grafted to Cabernet Sauvignon or Muscat vines. Quantifiable levels were found only in Cabernet franc, Cabernet Sauvignon, Merlot, Sauvignon blanc and Semillon, providing information on the genetic connection for the occurrence of MIBP in grapes. No MIBP was detected in the berries of Muscat blanc clusters grafted onto Cabernet Sauvignon vines when sampled at fruit maturity. MIBP was detected in all berries of Cabernet Sauvignon regardless the graft configuration. The data indicate that MIBP or its precursors originate in the berry and its formation depends upon grape genotype.

材料
製品番号
ブランド
製品内容

Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Sigma-Aldrich
2-イソブチル-3-メトキシピラジン, ≥99%, FG
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
2-Isobutyl-3-methoxypyrazine solution, certified reference material
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME StableFlexファイバー組み合わせキット, for use with manual holder
Supelco
SPME StableFlexファイバー組み合わせキット, needle size 23 ga, for use with autosampler
Sigma-Aldrich
2-イソブチル-3-メトキシピラジン, 99%
Supelco
SPMEファイバーアセンブリ、Carbowax・ポリエチレングリコール(PEG)コーティング, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder