380008
Ammonium bromide
99.999% trace metals basis
동의어(들):
Azanium bromide, Hydrobromic acid monoammoniate
로그인조직 및 계약 가격 보기
모든 사진(3)
About This Item
Linear Formula:
NH4Br
CAS Number:
Molecular Weight:
97.94
EC Number:
MDL number:
UNSPSC 코드:
12352302
eCl@ss:
38050407
PubChem Substance ID:
NACRES:
NA.23
분석:
99.999% trace metals basis
양식:
powder
추천 제품
vapor pressure
1 mmHg ( 198.3 °C)
Quality Level
분석
99.999% trace metals basis
양식
powder
불순물
≤15.0 ppm Trace Metal Analysis
mp
452 °C (lit.)
density
2.43 g/mL at 25 °C (lit.)
SMILES string
N.Br[H]
InChI
1S/BrH.H3N/h1H;1H3
InChI key
SWLVFNYSXGMGBS-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Lact. - Repr. 1B - STOT RE 1 - STOT SE 3
표적 기관
Central nervous system, Nervous system
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
Lot/Batch Number
이미 열람한 고객
Fredrik Hallberg et al.
Journal of magnetic resonance (San Diego, Calif. : 1997), 192(1), 69-77 (2008-02-22)
Although simple as a concept, electrophoretic NMR (eNMR) has so far failed to find wider application. Problems encountered are mainly due to disturbing and partly irreproducible convection-like bulk flow effects from both electro-osmosis and thermal convection. Additionally, bubble formation at
Erhong Duan et al.
Journal of hazardous materials, 194, 48-52 (2011-08-27)
The solubility of SO(2) in a binary mixture of water and caprolactam tetrabutyl ammonium bromide ionic liquid (CPL-TBAB IL) was investigated. Though the ionic liquid and water were fully miscible, a phase separation occurred when SO(2) was introduced into the
Catalytic synthesis of nonracemic azaproline derivatives by cyclization of β-alkynyl hydrazines under kinetic resolution conditions.
Pradip Maity et al.
Angewandte Chemie (International ed. in English), 50(36), 8338-8341 (2011-07-19)
Tawnya G Flick et al.
Analytical chemistry, 84(17), 7511-7517 (2012-08-14)
The presence of many salts, such as sodium chloride, can adversely affect the performance of native electrospray ionization mass spectrometry for the analysis of proteins and protein complexes by reducing the overall molecular ion abundances and distributing signal for any
Emilia Fisicaro et al.
The journal of physical chemistry. B, 109(5), 1744-1749 (2006-07-21)
The apparent and partial molar enthalpies, apparent molar volumes, and adiabatic compressibilities at 298 K of the aqueous solutions of the cationic gemini surfactants propanediyl-alpha,omega-bis(octyldimethylammonium bromide) (8-3-8) and propanediyl-alpha,omega-bis(dodecyldimethylammonium bromide) (12-3-12) have been measured as a function of concentration. The
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.