콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

93321

Sigma-Aldrich

TRIS Glycine buffer solution

BioUltra, 10× concentrate

동의어(들):

Blotting buffer solution

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41105319
NACRES:
NA.25

제품 라인

BioUltra

Quality Level

형태

liquid

품질

10× concentrate

구성

glycine, 1.92 M
TRIS, 0.25 M

불순물

insoluble matter, passes filter test
proteases, none detected

무기 잔류물

≤0.2%

pH

8.5-8.7

음이온 미량물

sulfate (SO42-): ≤50 mg/kg

양이온 미량물

Al: ≤5 mg/kg
As: ≤0.1 mg/kg
Ba: ≤5 mg/kg
Bi: ≤5 mg/kg
Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Li: ≤5 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Mo: ≤5 mg/kg
NH4+: ≤200 mg/kg
Na: ≤500 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Sr: ≤5 mg/kg
Zn: ≤5 mg/kg

λ

neat

UV 흡수

λ: 260 nm Amax: 0.1
λ: 280 nm Amax: 0.1

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Trizma is used in the formulation of buffer solutions in the pH range between 7.5 and 8.5. Tris buffer solutions are widely used in cell and molecular biology for processes such as protein and nucleic acid extraction and purification. TRIS Glycine buffer solution, 10X concentrate is diluted to a working concentration of 1X and pH adjusted as required. TRIS Glycine buffer (TGB) is frequently used in gel electrophoresis and ion-exchange chromatography applications.

기타 정보

Electrophoretic transfer of protein from polyacrylamide gels to nitrocellulose sheets: Procedure and some applications

Storage Class Code

10 - Combustible liquids

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Hongshan Liu et al.
Molecular vision, 15, 505-517 (2009-03-06)
To develop a new method of whole mount immunostaining that improves the penetration of staining reagents into the cornea and decreases non-specific binding and background. Adult mouse corneas were fixed overnight in 4% paraformaldehyde or a mixture of 4% paraformaldehyde
Guo-Min Tan et al.
Journal of chromatography. A, 1098(1-2), 131-137 (2005-11-30)
Ion-exchange electrochromatography with an oscillatory electric field perpendicular to mobile-phase flow driven by pressure (pIEEC) was developed with a column design of rectangle cross-section. The effect of electric field strength on the dynamic binding capacity (DBC) was examined by frontal
E R Frears et al.
Glycoconjugate journal, 16(6), 283-290 (1999-12-01)
IgG carries bi-antennary N-linked glycans which differ in degrees of galactosylation, core fucosylation and bisecting N-acetyl glucosamine. The majority of these are non-sialyated closely related neutral structures which can be resolved by HPLC analysis, but which are difficult to separate
Zhixin Wang et al.
Electrophoresis, 29(22), 4454-4462 (2008-11-28)
Multiple labeling of nucleic acids by intercalative dyes is a promising method for ultrasensitive nucleic acid assays. The properties of the fast dissociation and instability of dye-DNA complexes may prevent from their wide applications in CE-LIF nucleic acid analysis. Here
H Towbin et al.
Proceedings of the National Academy of Sciences of the United States of America, 76(9), 4350-4354 (1979-09-01)
A method has been devised for the electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets. The method results in quantitative transfer of ribosomal proteins from gels containing urea. For sodium dodecyl sulfate gels, the original band pattern was

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..