61074

Supelco

プロピオフェノン

analytical standard

別名:

エチルフェニルケトン

ログイン組織・契約価格を表示する


About This Item

化学式:
C6H5COC2H5
CAS番号:
分子量:
134.18
Beilstein:
606215
EC Number:
MDL番号:
UNSPSCコード:
85151701
PubChem Substance ID:
NACRES:
NA.24

グレード

analytical standard

品質水準

蒸気圧

1 mmHg ( 50 °C)

アッセイ

≥97.0% (GC)

シェルフライフ

limited shelf life, expiry date on the label

テクニック

HPLC: suitable
gas chromatography (GC): suitable

屈折率

n20/D 1.526 (lit.)
n20/D 1.527

bp

218 °C (lit.)

mp

17-19 °C (lit.)

密度

1.009 g/mL at 20 °C
1.009 g/mL at 25 °C (lit.)

アプリケーション

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

フォーマット

neat

SMILES記法

CCC(=O)c1ccccc1

InChI

1S/C9H10O/c1-2-9(10)8-6-4-3-5-7-8/h3-7H,2H2,1H3

InChI Key

KRIOVPPHQSLHCZ-UHFFFAOYSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

アプリケーション

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

保管分類コード

10 - Combustible liquids

WGK

WGK 2

引火点(°F)

210.2 °F - closed cup

引火点(℃)

99 °C - closed cup


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

消防法

第4類:引火性液体
第三石油類
危険等級III
非水溶性液体

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

61074-VAR:
61074-BULK:
61074-5ML:
61074-1ML:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Adriana Arigò et al.
Journal of chromatography. A, 1649, 462183-462183 (2021-05-27)
In the European Union, cosmetic products are regulated by the Cosmetics Regulation (EC) No. 1223/2009. The Analytical Working Group of the International Fragrance Association (IFRA) suggested that a new sensitive analytical method is needed to determine psoralens in finished cosmetic
Martin Gilar et al.
Journal of chromatography. A, 1381, 110-117 (2015-01-22)
Sample introduction in microfluidic liquid chromatography often generates wide zones rather than peaks, especially when a large sample volume (relative to column volume) is injected. Formation of wide injection zones can be further amplified when the sample is dissolved in
Martin Gilar et al.
Journal of chromatography. A, 1390, 86-94 (2015-03-10)
Chromatographic zone broadening is a common issue in microfluidic chromatography, where the sample volume introduced on column often exceeds the column void volume. To better understand the propagation of wide chromatographic zones on a separation device, a series of MS
Yan Ma et al.
Journal of chromatography. A, 1383, 47-57 (2015-02-05)
Prototype small-size (1.0mm I.D., 5cm long) columns for reversed-phase HPLC were evaluated in relation to instrument requirements. The performance of three types of columns, monolithic silica and particulate silica (2μm, totally porous and 2.6μm, core-shell particles) was studied in the

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)