コンテンツへスキップ
Merck
  • A solid-phase extraction method for rapidly determining the adsorption coefficient of pharmaceuticals in sewage sludge.

A solid-phase extraction method for rapidly determining the adsorption coefficient of pharmaceuticals in sewage sludge.

Water research (2014-10-10)
Laurence Berthod, Gary Roberts, David C Whitley, Alan Sharpe, Graham A Mills
要旨

The partitioning of pharmaceuticals in the environment can be assessed by measuring their adsorption coefficients (Kd) between aqueous and solid phases. Measuring this coefficient in sewage sludge gives an indication of their partitioning behaviour in a wastewater treatment plant and hence contributes to an understanding of their subsequent fate. The regulatory approved method for measuring Kd in sewage sludge is the US Environmental Protection Agency's Office of Prevention, Pesticides and Toxic Substances (OPPTS) guideline 835.1110, which is labour intensive and time consuming. We describe an alternative method for measuring the Kd of pharmaceuticals in sewage sludge using a modified solid-phase extraction (SPE) technique. SPE cartridges were packed at different sludge/PTFE ratios (0.4, 6.0, 24.0 and 40.0% w/w sludge) and eluted with phosphate buffer at pH 7.4. The approach was tested initially using three pharmaceuticals (clofibric acid, diclofenac and oxytetracycline) that covered a range of Kd values. Subsequently, the sorption behaviour of ten further pharmaceuticals with varying physico-chemical properties was evaluated. Results from the SPE method were comparable to those of the OPPTS test, with a correlation coefficient of 0.93 between the two approaches. SPE cartridges packed with sludge and PTFE were stable for up to one year; use within one month reduced variability in measurements (to a maximum of 0.6 log units). The SPE method is low-cost, easy to use and enables the rapid measurement of Kd values for a large number of chemicals. It can be used as an alternative to the more laborious full OPPTS test in environmental fate studies and risk assessments.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, ≥99.9%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
リン酸カリウム 一塩基性, ACS reagent, ≥99.0%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
リン酸カリウム 二塩基性, ACS reagent, ≥98%
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
リン酸カリウム 一塩基性, powder, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99.0%
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
リン酸カリウム 二塩基性, puriss. p.a., ACS reagent, anhydrous, ≥99.0% (T)
Sigma-Aldrich
リン酸カリウム 一塩基性, buffer substance, anhydrous, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., 99.5-100.5%
Sigma-Aldrich
リン酸ナトリウム, 96%
Sigma-Aldrich
イブプロフェン, ≥98% (GC)
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
リン酸カリウム 一塩基性, meets analytical specification of Ph. Eur., NF, E340, anhydrous, 98-100.5% (calc. to the dried substance)
Sigma-Aldrich
リン酸カリウム 一塩基性, for molecular biology, ≥98.0%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
リン酸カリウム 二塩基性, anhydrous, for luminescence, for molecular biology, BioUltra, ≥99.0% (T)
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
USP
メチルアルコール, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Sigma-Aldrich
リン酸カリウム 二塩基性 溶液, 1.0 M